Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit Review Detail
Review Status: Requires Resubmit
Review Details: MANUFACTURED/MOBILE/PARK MODEL HOME v.1
Permit Number - TC-FBB-0324-00049
Review Name: MANUFACTURED/MOBILE/PARK MODEL HOME v.1
Review Status: Requires Resubmit
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
04/10/2024 | Site Engineering | NOT REQUIRED | |||
04/17/2024 | Bldg Permits - Post Review | PENDING ASSIGNMENT | |||
03/28/2024 | Residential Building | REQUIRES RESUBMIT | TC-FBB-0324-00049 PLAN REVIEW COMMENTS Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. For facilitating a shorter back check time, please provide updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment updates; revisions are processed if changes occur after the permit is issued. SCOPE OF REVIEW: The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2018 International Residential Code and 2018 International Energy Conservation Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions, and concerns before permit approval. SITE PLAN: 1. Show the location and size of buildings, utility meters and gas, water, electrical, and sewer, R106.1.1. Each dwelling requires an appropriate source of electrical and water supply. Show the location and size of lines with connection points, R106.1.1. Identify the utility lines requiring upgrade or replacement. PLUMBING PLANS: 1. Tucson Water Department limits flow rates for the water meter size in compliance with P2903.7. Show an appropriate yard pipe bypassing the existing dwelling and show an appropriate water meter size. ELECTRICAL PLANS: 1. TEP may require the service panel for the property at the closest building to the service transformer. A service line change or a new meter location must be coordinated with TEP for approval. 2. Provide a minimum service conductor rating of #3 copper 75 degree C for the 100 AMP feeder, E3602.1 & E3603.1. OUTDOOR LIGHTING CODE 1. Show the proposed fixture as full cut-off FCO style or provide an Outdoor Lighting Calculation including all exterior fixtures on the property for determining exterior lighting limits. Show full cutoff fixtures were located within 25 feet from the property line OLC 401.3.3. If you have any questions, please contact: PDSD-Residential@tucsonaz.gov City of Tucson Residential Plan Review Submit a corrected plan set at https://www.tucsonaz.gov/pdsd |
||
04/17/2024 | Site Zoning | REQUIRES RESUBMIT | Per City of Tucson Unified Development Code a manufactured home is a permitted use in the R-1 zone (UDC 4.8-2), with the following use specific standards. -A manufactured housing unit is not considered a dwelling for the purposes of this section, unless it is located in a subdivision recorded after January 1, 1982, and not located in a re-subdivision of any subdivision recorded prior to January 1, 1982. The property is located in the Littletown No.1 subdivision, recorded in 1955. Per the above standard a manufactured home is not permitted. If you have any questions about the above comments reach out to Nathan Herrera at Nathan.Herrera@tucsonaz.gov |
||
03/28/2024 | PDSD Application Completeness | REVIEW COMPLETED | The plan submitted lists Unit 2 and the unit specified is not attached to the address and a pre issuance addressing condition has been placed on permit. Please contact Pima County Addressing at addressing@pima.gov or 520-724-9512 to verify and or add the unit. Note, a resubmittal and address change may be required. |