Permit Review Detail
Review Status: Requires Resubmit
Review Details: SHIPPING CONTAINER v.3
Permit Number - TC-FBB-0324-00047
Review Name: SHIPPING CONTAINER v.3
Review Status: Requires Resubmit
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
04/25/2024 | Site Engineering | NOT REQUIRED | |||
04/30/2024 | Bldg Permits - Post Review | PENDING ASSIGNMENT | |||
04/30/2024 | Residential Building | REQUIRES RESUBMIT | Please submit your revised documents along with a detailed response letter, which states how all Building Review Section comments were addressed. The submitted documents were incomplete, as such, additional comments may arise after corrections have been addressed by the designer. 1. Structural Calculations: Page 87 of the structural calculations include values for Flagstaff, AZ. Please provide the reason Flagstaff was used in these calculations. R106.1.1 2. Please provide the following information as required by the City of Tucson Residential submittal requirements. City of Tucson Adopted Design Ordinances – handicap provisions, solar water, photovoltaic and grey water preparations. IRC 106.1.1 3. Sheet T1.0: Please amend plans to include a sheet index to list all the sheets in the plans set, each sheet should have a unique label to differentiate the sheets form each other. For example, the first two sheets are labeled as T1.0. IRC R106.1.1 4. Sheet T1.0: Please amend Code Review to add these applicable codes to the list. IRC R106.1.1 2018 IBC, 2017 NEC, 2012 City of Tucson/Pima County Outdoor Lighting Code, Local Amendments to Above Codes ( www.tucsonaz.gov/pdsd/building-codes ) Treat this as a typical note. 5. Sheet T1.0: Please indicate the size of the house connection sewer, and the total number of DFU’s for new and existing structures to ensure proper sizing of the house connection sewer. IRC P3004, Table P3004.1 and Table P3005.4.2 6. 2nd Sheet T1.0: Please update General Note and Conditions by clear text as current notes are not legible. IRC R106.1.1 7. 2nd Sheet T1.0: Please update General Floor Plan Note #2 to specify tile backerboard to be listed in Table R702.4.2. IRC R106.1.1 8. Sheet A1.5: Please amend plans to provide the shower receptor dimensions and type, shower head location, enclosure type and type and size of door, if used, for the shower in the bathroom connected to the bedroom. IRC R106.1.1 P2708, P2709 Additionally, provide shower pan construction details or provide ESR# if using a manufactured unit. IRC R106.1.1 9. Sheet A3.0: Please amend plans to remove (E) Call Center and Proposed Tenant Side notes from detail 4/A3.0 IRC R106.1.1 10. Sheet A3.0: Please amend plans to provide the ESR# for the Sprayed Foam and the Polycarbonate insulation. Treat as a typical note. IRC R106.1.1 11. Sheet A3.0: Please amend plans sheets to indicate the methos of providing under-floor ventilation. IRC R408.1 12. Sheet S0.0: Please provide structural sheets S0.0, S3.0, and S4.0 signed by the Engineer of Record as noted on the structural calculations. The calculations are noted to indicate; “The following calculations & analysis documents are site and scope specific. Referenced materials, values, and conditions are deemed valid only at the time of analysis per location and do not purport to have further application. As typically the case, these calculations & analysis documents accompany architectural and engineering plan sheets, constituting a complete set of construction documentation. For the calculations & analysis documents to be deemed valid the sheets must be approved for construction and sealed by engineer of record.” Please resolve. IRC 106.1.1 13. Sheet S0.0,T1.0: The design loads that do not seem to match local conditions. Please indicate why these values are being used. IRC R106.1.1 14. Sheet P1.0: Please amend plans to provide a fixture unit calculation for the sizing of the water service line, water meter based on the current adopted code. Be sure to include both buildings in this calculation as they share a water meter. P2903 Appendix P 15. Sheet P1.0: Please provide water heater manufacturer’s cut sheet with next submittal. R106.1.1 16. Sheet M1.0: All new mechanical system installations shall comply with mechanical system sizing per ACCA (Manual J – for Building Heating/Cooling loads), ACCA (Manual S – for Equipment sizing), per IRC M1401.3, IRC M1601.1, IRC N1103.6, IECC R403.6, or other approved methods. Provide heating and cooling compliance calculations and methodology on plans. IRC 106.1.1 17. Sheet M1.0: Please amend plans to provide exhaust fan in laundry room and provide louvered door or alternate method of venting laundry room door. IRC R303.3 18. Sheet E0.0: Sheet T1.0 indicates a 125A SES and the Electrical Sheet E0.0 indicates a 100A MLO. Sub-Pane Please coordinate so both drawings show the same information IRC R106.1.1 19. Sheet E0.0: Please update General Electrical note 14. to read: Branch circuits that supply 120-volt, single-phase, 15- and 20-ampere outlets installed in kitchens, family rooms, dining rooms, living rooms, parlors, libraries, dens, bedrooms, sunrooms, recreations rooms, closets, hallways, laundry areas and similar rooms or areas shall be Arc-Fault protected E3902.16 a. Please remove the reference to exempt GFI and WP/GFI receptacles as they require AFCI protection as well. IRC R106.1.1 20. Sheet E0.0: Please amend plans to provide a disconnecting means for Sub-panel E. E3601.6 and E3601.7. For example, provide a main breaker at the sub-panel. 21. Sheet E0.0: Please amend plans to provide electrical load calculations for the existing 200A main panel to ensure it is sufficiently sized for both electrical loads. E3602.2 22. Sheet E0.0: Amend plans to note main bonding jumper to not be used in sub panel E3607.3.2 23. Sheet E0.0: Please clarify why two Electrical riser diagrams are present on this sheet and for what purpose. IRC R106.1.1 Sheet E0.0: Please amend plans as UFFER does not appear to be possible, as no footings are 20 feet in length. Please provide a grounding electrode system such as two ground rods per E3608.1.4 and E3608.3.4.1 and show on electrical riser diagram. IRC R106.1.1 Sheet E1.2: Please amend plans to show the location of the Sub-panel E on the electrical floor plan. IRC R106.1.1 Sheet E1.2: Please provide manufacturer's cut sheet for water heater with next submittal IRC 106.1.1 Sheet E1.2: Please indicate compliance with the 2012 outdoor lighting code and provide exterior lighting fixture cut sheets, watts, and color temperature for the proposed fixtures. This calculation will include all the exterior lighting on this parcel. IRC R106.1.1 Mark Masek Plans Examiner – Building Safety Planning and Development Services | City of Tucson main 520.837.4994 email mark.masek@tucsonaz.gov |
||
04/29/2024 | Site Zoning | REQUIRES RESUBMIT | FROM: PDSD Zoning Review Section PROJECT: TC-FBB-0324-00047 130 N WARREN AV Unit: 2. – R-2 2nd Dwelling Unit (1st Review) TRANSMITTAL DATE: April 29, 2024 COMMENTS: Resubmit revised drawings along with a detailed response letter, which states how all Zoning Review Section comments were addressed. This site is located in the R-2 zone (UDC 4.7.9). A two (2) single-family residence (SFR) is a permitted use in this zone (Table 4.8-2). See Use-Specific Standards 4.9.7.B.6, .9, & .10. 1. The north and south property distance 212” is not correct. Review the Altadina Heights final plat and provided the correct dimensions. 2. The lot coverage calculation is not correct. Per UDC Article 6.4.3.C.1.a Roofed areas, porches, open on at least one side are not included in the calculation. If you have any questions about this transmittal, please contact Zone1.desk@tucsonaz.gov. |
||
03/27/2024 | PDSD Application Completeness | REVIEW COMPLETED |