Review Date Reviewer's Name Type of Review Description Status Comments
03/18/2024 Residential Building APPROVED
04/02/2024 Site Engineering NOT REQUIRED
04/03/2024 Bldg Permits - Post Review Express PENDING ASSIGNMENT
04/03/2024 Site Zoning REQUIRES RESUBMIT FROM: PDSD Zoning Review Section

PROJECT: TC-FBB-0324-00042
3313 N FLANWILL BL UNIT 2 – R-3
Manufactured home and metal perimeter fence (1st Review)

TRANSMITTAL DATE: April 3, 2024

COMMENTS: Please resubmit revised drawings along with a detailed response letter, which states how all Zoning Review Section comments were addressed.

This site is located in the R-3 zone (UDC 4.7.12). A Manufactured Home is a permitted use in this zone (Table 4.8-2), subject to Use Specific Standard 4.9.7.B.6.

1. The proposed 14’ x 64’ manufactured home does not meet the Unified Development Code (UDC) definition of a manufactured home. Per UDC Article 11.3.7.A.2 Manufacture Housing, a multisectional mobile home dwelling manufactured after June 15, 1976, to standards established by the U.S. Department of Housing and Urban Development that has external dimensions of at least 24 feet by 40 feet and is installed on a permanent foundation. A manufactured housing unit is considered equivalent to a single-family dwelling. To be considered a manufactured housing unit under this UDC , a wall must be installed continuously, except for ventilation and access, along the entire perimeter of the unit between the unit and the ground to give it the appearance of a site -built house. The wall must be of masonry construction or similar material. The tongue, axles, transporting lights, and towing apparatus must be removed before occupancy. A rezoing of the property will be required to put a single wide on this parcel.

If you have any questions about this transmittal, please contact Zone1.desk@tucsonaz.gov.
03/18/2024 PDSD Application Completeness Express REVIEW COMPLETED