Permit Number: TC-FBB-0125-00009
Parcel: 107113400

Review Status: Requires Resubmit

Review Details: MANUFACTURED/MOBILE/PARK MODEL HOME v.1

Permit Number - TC-FBB-0125-00009
Review Name: MANUFACTURED/MOBILE/PARK MODEL HOME v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
03/05/2025 Bldg Permits - Post Review Express PENDING ASSIGNMENT
03/05/2025 Site Engineering PENDING ASSIGNMENT TC-FBB-0125-00009
183 E PLACITA ESTRELLA

Site engineering comments are as follows:
1. This Factory Built Building installation lies within a regulated floodplain, Navajo Wash, and requires a Floodplain Use Permit (FUP) with Elevation Certificate. The base flood elevation is 2340.22ft NAVD88. The required elevation of the lowest structural member of the building is 2341.22ft NAVD88.

Please start a new FUP with Elevation Certificate at our permit application web page:
https://tdc-online.tucsonaz.gov/#/home

Ryan Insalaco – ryan.insalaco@tucsonaz.gov
02/12/2025 Residential Building REQUIRES RESUBMIT TC-FBB-0125-00009
PLAN REVIEW COMMENTS

Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. For facilitating a shorter back check time, please provide updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment revisions.

SCOPE OF REVIEW:

The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2018 International Residential Code and 2018 International Energy Conservation Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions, and concerns before permit approval.

GENERAL REQUIREMENTS:

Provide a response letter on separate file with the updated construction plan set.

1. Provide the set-up permit number provided by https://housing.az.gov

If you have any questions, please contact:
Ken Van Karsen
PDSD-Residential@tucsonaz.gov
City of Tucson Residential Plan Review
02/26/2025 Site Zoning REQUIRES RESUBMIT FROM: PDSD Zoning Review Section

PROJECT: TC-FBB-0125-00009
183 E PLACITA ESTRELLA. – R-2
MANUFACTURED HOME (1st Review)

TRANSMITTAL DATE: February 26, 2025

COMMENTS: Please resubmit revised drawings along with a detailed response letter, which states how all Zoning Review Section comments were addressed.

This site is located in the R-2 zone (UDC 4.7.9). A Manufactured Home is a permitted use in this zone (Table 4.8-2). See Use-Specific Standards 4.9.7.B.6, .9, & .10.

1. The lot coverage calculation is not correct. Per UDC Article 6.4.3.B.3.b Vehicular use areas, measured within the outside edges of any area allocated to vehicle use, whether improved or unimproved are included in the lot coverage.

2. The property shape does not match the Estrella Heights Subdivision found at: https://onbase.pima.gov/publicaccess/DS_NextGen_Single/etc/cq/results.html?cqid=240&OBKey__552_1=56059. Review this plat and correct the lot shape and provide all dimensions.

3. Review the final plat mentioned in comment 2 and clearly show all easements that are located on the property full dimensioned.

4. Clarify what the dashed line is for shown 15’ from centerline of Placita Estrella.

5. Review tentative plat S99-059 found at: https://pro.tucsonaz.gov/activity_search/?csrfmiddlewaretoken=uer2XcsQyNtZ7Ijwazt77v7KizWyQ1GDj7PLzgybLPCuuEHzqTtTAT0yPgAgPFnv&activity_number=S99-059, and clearly show the curb along Placita Estrella and provide a dimension from centerline to the face of curb.

6. Provide a dimension from the proposed manufactured home south to the face of curb.

7. Review Construction Plan I-822B, sheet 10 found at: https://maps-and-records.tucsonaz.gov/construction-plans/details/I-822B, and show the curb along Estrella and provide the correct dimension from face of curb to the east property line.

8. Clearly demonstrate that all requirements of UDC Article 4.9.7.B.6 are met.

The Unified Development Code (UDC) can be found at: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Codes/Zoning-Code.

If you have any questions about this transmittal, please contact Zone1.desk@tucsonaz.gov.
02/12/2025 PDSD Application Completeness Express REVIEW COMPLETED