Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Number: TC-FBB-0125-00007
Parcel: 14041009A

Review Status: Requires Resubmit

Review Details: PERMANENT MODULAR v.3

Permit Number - TC-FBB-0125-00007
Review Name: PERMANENT MODULAR v.3
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
05/20/2025 Commercial Building - Standard APPROVED
05/21/2025 Site Zoning - Standard APPROVED
05/19/2025 Site Engineering - Standard NOT REQUIRED
05/21/2025 Bldg Permits - Post Review Express PENDING ASSIGNMENT
05/21/2025 Commercial Electrical - Standard REQUIRES RESUBMIT Commercial Electrical Review TC-FBB-0125-00007 (3350 E VALENCIA RD TUCSON, AZ 85706)
Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide updated Plans/calculations and a written response Letter to each of the notated items indicating action taken. Resubmitted plans that do not contain a written response Letter addressing each of the notated items indicating action taken, may be delayed until response letter is received.
Code reference, 2018 International Building Code (IBC), 2017 National Electrical Code (NEC), 2012 Outdoor Lighting Code (OLC).

Outdoor Lighting Review:
https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/building-code/2012_outdoor_lighting_code_.pdf

1. Show lamps with a maximum of 3500K color temperature, OLC 402.1. REF Sheet E2, Lighting & Receptacle Notes.
2. Show the two new lights as full cutoff, OLC 401.2.1.
3. Fixtures installed under canopies and overhangs. Outdoor lighting fixtures shall not be counted in determining the total light output when they are full cutoff light fixtures installed under canopies, building overhangs, or roof eaves, OLC 401.2.1(3).

4. Provide Curfew lighting controls If applicable Per section 403.


Contact Jeremy Hamblin with any questions: Jeremy.hamblin@tucsonaz.gov
05/20/2025 Commercial Plumbing - Standard REQUIRES RESUBMIT 1. Provide a civil site plan showing the route of the building sewer to the public sewer. Reference: Section 107.2.1, IBC 2018.
2. Identify the material of construction for the existing private building sewer that will be located under the proposed modular building. Reference: Sections 702.2 and 702.3, IPC 2018.
3. Provide the rim elevation of the next upstream sanitary manhole and the first-floor elevation. Determine the need for a backwater valve per Section 714.1, IPC 2018, as amended by the City of Tucson.
05/21/2025 Fire New Construction - Standard REVIEW COMPLETED
04/21/2025 PDSD Application Completeness Express REVIEW COMPLETED