| 03/26/2026 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 03/26/2026 | Other Inspection Reports (Deferred Submittal) Express | REQUIRES RESUBMIT | ACTIVITY NO. TC-FBB-0125-00007 ADDRESS/PARCEL: (3350 E VALENCIA RD TUCSON, AZ 85706) Submit your revised drawings along with a detailed response letter, which states how all Building Review Section comments were addressed. Please paste the review comment individually and enter your response directly below it. Please do this for every comment. Review will not proceed without the response letter. The submitted documents were incomplete and a thorough plan review could not be performed. Please be aware, new comments may arise with the next review. Should the above not followed, it may delay your approval. Additionally, please submit complete copies of all permit documents (i.e. plans, calculations, reports, etc.) even if they have not been changed. Should you have any questions about these Commercial Building comments, I can be reached at Justin.Eder@tucsonaz.gov or 520-837-4976. COMMENTS: Even though this permit is pass its due date, the City held on to this permit with the hope that the applicant is able to resolve the chemical quantity/volume issue. At the moment, the City have to send it back with the hope that a response in the positive will be submitted back into the building permit record online. 1. TUCSON FIRE DEPARTMENT a. Per our phone conversation, the applicant to coordinate with Tucson Fire Department. b. The applicant to contact Patricia Shelton at Patricia.Shelton@tucsonaz.gov or John Vincent. c. The applicant to submit the necessary document regarding the quantity/volume of chemicals proposed. d. The aggregate amount of each chemical to be analyzed making sure none is over the aggregate allowable quantity. i. Please take a look at closely the aggregate total of the flammable liquids and solids. ii. Please take a look at closely the aggregate total of the toxic liquids and toxic solids. iii. Please take a look at any of the other chemicals that may have issue with the aggregate total allowable. e. Once submitted to Tucson Fire Department, please obtain their approval. NOTE: Tucson Fire indicated they have not received submission recently. f. NOTE: Please also inquire with Tucson Fire regarding the required Fire Operational Permit for hazardous materials. 2. STATE APPROVAL a. Per our phone conversation, the applicant to confirm the direction the State of Arizona gave to the applicant. b. Is the State taking back their FBB (Factory Built Structure) approval of the structure final and the H classification must be attached to the FBB. Should this be the case, is the state requiring the local jurisdiction to review/approve the entire application/submission without the state’s hand into it which means local jurisdiction will also conduct all inspection like a custom project will be handled including opening walls or enclosed assemblies for inspection. c. Will the State allow the applicant to resubmit and allow the applicant to correct the issue. Will the State work with the applicant to obtain back their previous FBB approval, hence keeping the S-1 classification. d. Applicant to coordinate with the State and confirm exactly what documentation the State will require in order for the above to occur, what and whose approval will be required by the State. 3. CITY OF TUCSON a. Once approval has been obtained from Tucson Fire Department, please respond to these comments and submit into your building permit record online for City review and approval. b. Should the City approve the submission, the City will require the applicant to submit back to the State of Arizona for their review and approval. c. Once the State approval is obtained, the applicant to submit the approved chemical list/quantiy, approved drawings, and any document the state issued to the applicant into the building permit record online for City of Tucson review and approval. 4. Please resubmit. |
||
| 03/16/2026 | PDSD Application Completeness Express | REVIEW COMPLETED |