Permit Review Detail
Review Status: Requires Resubmit
Review Details: DEMOLITION v.1
Permit Number - TC-DMO-1026-00179
Review Name: DEMOLITION v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 10/15/2026 | Site Engineering Fast | NOT REQUIRED | |||
| 10/23/2026 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 10/15/2026 | Addressing Validation | REQUIRES RESUBMIT | If you have any questions, please contact cdrc@tucsonaz.gov The construction plans are missing the project address on every page. After this review, please resubmit the construction plans with project address on every page. Step-by-Step instructions on how to resubmit: https://www.tucsonaz.gov/files/sharedassets/public/pdsd/documents/tdc-faq/new-pdfs/revisions-and-resubmittals.pdf |
||
| 10/23/2026 | Commercial Building Fast | REQUIRES RESUBMIT | ACTIVITY NO. TC-DMO-1026-00179 ADDRESS/PARCEL: (1818 S AVENIDA DEL SOL TUCSON, AZ 85710) Submit your revised drawings along with a ***detailed response letter***, which states how all Building Review Section comments were addressed. Please paste the review comment individually and enter your response directly below it. Please do this for every comment. Review will not proceed without the response letter. The submitted documents were incomplete and a thorough plan review could not be performed. Please be aware, new comments may arise with the next review. Should the above not followed, it may delay your approval. Additionally, please submit complete copies of all permit documents (i.e. plans, calculations, reports, etc.) even if they have not been changed. Should you have any questions about these Commercial Building comments, I can be reached at Justin.Eder@tucsonaz.gov or 520-837-4976. COMMENTS: 1. SUBMITTED EXISTING DRAWINGS: Please place a label on every page, “FOR REFERENCE ONLY”. 2. Provide a Site Plan drawing, locating and labeling the area to be demolished. Please label structures surrounding this incinerator to remain. 3. REMEDIATION & NESHAP: a. The City of Tucson thank you for conducting testing of the subject. Please submit the document/report resulting from the test done. b. Please submit the NESHAP report confirming materials such as asbestos are not present on the site and friable material are not present. 4. NOTICE OF DEMOLITION FORM: Please enter the date the notification mail was sent out. Please answer the question, “Owner of Property to be Demolished”. 5. Please resubmit. |
||
| 10/15/2026 | Fire New Construction Express | REQUIRES RESUBMIT | No indication on submitted plans to what/where demo is to be done. *Please provide plans showing location and scope of work to be done. |
||
| 10/15/2026 | Historic Fast | REQUIRES RESUBMIT | It is unclear what exactly is proposed for demolition. Please provide a site plan clearly labeling and showing what portion of the building will be demolished. It sounds like the brick tower will be demolished. If any portion of the existing building is to be demolished, a completed Architectural Demolition Documentation Package is required. Please review and complete this form and provide required materials for Minor Documentation: https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/planning-amp-zoning/historic-property-demolition-information-form_100926.pdf. | ||
| 10/21/2026 | Site Zoning Fast | REQUIRES RESUBMIT | PDSD TRANSMITTAL FROM: Jeffrey W. Cassidy, Planner I Planning & Development Services Department – Current Zoning Review Section, Commercial PROJECT: TC-DMO-1026-00179 – Commercial – Winnie Wheeler Elem Sch RR Incinerator damaged by storm 1818 S AVENIDA DEL SOL TUCSON, AZ 85710 (R-1 Zoning) Demolition Plan Review – 1st Review TRANSMITTAL DATE: October 21, 2026 1. COMMENT: No detailed site plan was provided communicating the extent of the demolition scope. Either a) Provide a new, scaled site plan of the described scope or b) Clearly demarcate on the drawing package provided where the entirety of the scope will take place. This assumes the existing drawing package provided clearly indicates all areas affected/intended for demolition. 2. COMMENT: Refer to Historic reviewer comments for potential need to provide additional documentation if existing building area(s) are also affected/intended for demolition as the county property record indicates the structure was approximately built in 1959. Depending on the scope extent, per UDC 3.12.1.A this scope may require more documentation. 3. COMMENT: Additional comments may be forthcoming on the next review based on responses to Zoning and other PDSD reviewer comments. RESUBMITTAL OF THE FOLLOWING IS REQUIRED: 4. COMMENT: Corrected commercial building permit. 5. COMMENT: Provide a detailed response letter with your submittal that clearly shows how you have addressed all Zoning comments. Instructions for resubmittal - https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/tdc-faq/old-pdfs/double-old/resubmittals.pdf If you have any questions about this transmittal, please contact jeffrey.cassidy@tucsonaz.gov The Unified Development Code (UDC) can be found at: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Codes/Zoning-Code . |
||
| 10/22/2026 | Entitlements Fast | REVIEW COMPLETED | |||
| 10/15/2026 | PDSD Application Completeness Express | REVIEW COMPLETED |