Permit Review Detail
Review Status: Requires Resubmit
Review Details: DEMOLITION v.3
Permit Number - TC-DMO-0824-00174
Review Name: DEMOLITION v.3
Review Status: Requires Resubmit
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
08/28/2024 | Commercial Electrical | APPROVED | DEMO ONLY | ||
08/26/2024 | Site Zoning | APPROVED | |||
08/28/2024 | Site Engineering | NOT REQUIRED | |||
08/28/2024 | Bldg Permits - Post Review | PENDING ASSIGNMENT | |||
08/26/2024 | Commercial Building | REQUIRES RESUBMIT | ACTIVITY NO. TC-DMO-0824-00174 ADDRESS/PARCEL: (2510 N WINSTEL BL Unit:BLDG 2 UNIT 18 TUCSON, AZ 85716) Submit your revised drawings along with a detailed response letter, which states how all Building Review Section comments were addressed. The submitted documents were incomplete and a thorough plan review could not be performed. Please be aware, new comments may arise with the next review. Review will not proceed without the response letter. COMMENTS: 1. Submit a Site Plan. Locate/label the unit on the site plan. 2. Address: Address does not match between drawings and building permit address. Please coordinate with Pima Addressing Department at 520-724-9512 and ask for Nicholas Jordan. 3. Provide drawings, Identify/label the following on the plans: Fire partition with fire-resistance rating of not less than 1 hour per IBC 402.4.2.1 and IBC 708 extend from the top of the foundation or floor/ceiling assembly below to the underside of the floor or roof sheathing, deck or slab above shall have penetration complying to IBC 714 and joints complying with IBC 715 protected by an approved fire-resistant joint system to resist the passage of fire for a time period not less than the required fire-resistance rating of the wall, floor or roof in or between which the system is installed. 4. Provide the following values for the replacement windows: SHGC and U values. 5. Please confirm whether wall insulations are being installed replacing damaged insulations. 6. NOTE: This is demolition only permit. Correct the drawings to reflect just demolition information. 7. NOTE: Should you want a permit that covers both demolition and repair work, please withdraw this demolition permit and apply for a building permit that covers both demolition and repair work. 8. Please resubmit. |
||
08/28/2024 | Commercial Mechanical | REQUIRES RESUBMIT | This is an interior demolition permit only. Resubmit as a building permit to accomplish all of the work. | ||
08/28/2024 | Commercial Plumbing | REQUIRES RESUBMIT | This is an interior demolition permit only. Resubmit as a building permit to accomplish all of the work. | ||
08/20/2024 | Fire New Construction | REVIEW COMPLETED | |||
08/19/2024 | PDSD Application Completeness | REVIEW COMPLETED | Commercial Interior Only Demolition Permit. All other tenant improvements/repairs must be applied for separately as a Commercial addition/Alterations permit. |