Review Status: Requires Resubmit

Review Details: DEMOLITION v.1

Permit Number - TC-DMO-0623-00146
Review Name: DEMOLITION v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
07/14/2023 Historic NOT REQUIRED Not required - interior demolition does not trigger historic review.
06/29/2023 Site Engineering NOT REQUIRED
07/27/2023 Bldg Permits - Post Review PENDING ASSIGNMENT
07/27/2023 Commercial Building REQUIRES RESUBMIT 1. Storefront reconfigured to add a double door entry. Ensure that the Fenestrations shall have U-factor of 0.4 or better and Solar Heat Gain Coefficient of 0.25 or better.
2. Submit a separate Sign permit.
3. Show your parking requirement calculation and reflect this on your site plan.
4. Provide exhibits for the handicap stall standards along with the accessible striped areas and signages to include sign on posts.
5. Provide the required bicycle racks as well.
6. Provide the delivery stall as well.
7. Add a note on the floor plan indicating that the demising wall is to be from floor concrete slab to the underside of the roof sheathing fire rated and uses fire rated sealants.
8. Show the knee guards at the sinks protection from scalding complying to ANSI 117
9. Show the door pressure being applied complying to IBC and ANSI 117, this to include the restroom doors as well.
10. The required filtration system eliminating the cannabis sativa's scent is missing in this package. Please do make sure to provide this system complying with the jurisdiction's requirement.
11. You applied for a Demolition Permit. Please withdraw this permit and apply for the correct building permit type. It should be for a Commercial Tenant Improvement building permit.
07/18/2023 Commercial Electrical REQUIRES RESUBMIT Please address the electrical plan review comments and provide a written response.

Provide detailed information as to the scope of demo work associated with the lighting plan.

Ref; 2018 IBC section 107.2.1, 2017 NEC
07/17/2023 Commercial Mechanical REQUIRES RESUBMIT Apply for the correct permit: Commercial Additional/Alteration.
07/17/2023 Commercial Plumbing REQUIRES RESUBMIT Apply for the correct permit: Commercial Additional/Alteration.
06/26/2023 Site Zoning REQUIRES RESUBMIT ZONING REVIEW TRANSMITTAL

FROM: PDSD Zoning Review

PROJECT:
TC-DMO-0623-00146
1010 S. Freeway, Bldg A – C-2
Partial Exterior Demo

TRANSMITTAL: June 26, 2023
COMMENTS: the following comments are relative to an application for Architectural Documentation prior to demolition of historic buildings (UDC 3.12.1).
& .10.

The Pima County Assessor’s effective construction date for your building or structure is 1959. The actual construction date may be earlier.
Buildings, portions of buildings or structures that are 50 years of age or older must be architecturally documented prior to demolition. Documentation will be reviewed and approved by the Historic Preservation Office before a permit is issued.
Demolition (Historic and Older Structures) Application and General Information may be downloaded (PDF) at https://www.tucsonaz.gov/pdsd/all-application-forms-submittal-requirements
Return completed documentation to PDSDHistoric@tucsonaz.gov. Applicant will be contacted within 5 working days if additional materials are required for review.
06/27/2023 Fire New Construction REVIEW COMPLETED
06/22/2023 PDSD Application Completeness REVIEW COMPLETED