Permit Review Detail
Review Status: Requires Resubmit
Review Details: DEMOLITION v.2
Permit Number - TC-DMO-0526-00074
Review Name: DEMOLITION v.2
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 05/20/2026 | Residential Building Fast | APPROVED | |||
| 05/20/2026 | Residential Engineering Express | NOT REQUIRED | |||
| 05/20/2026 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 05/20/2026 | Residential Zoning Express | REQUIRES RESUBMIT | PDSD TRANSMITTAL FROM: Roxanne Johnston Planner PROJECT: TC-DMO-0526-00074 3759 E Sylvane St., Tucson, AZ 85713 Demo (1st Review) TRANSMITTAL DATE: 05/20/2026 This site is located within the R-2 Zone (UDC 4.7.9). A single-family residence is a permitted use in this zone (Table 4.8-2) subject to Use Specific Standards 4.9.7.B.6, .9, & .10. RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Correct plans, as noted in the comments below, along with a response letter indicating how all Site Zoning comments were addressed. 1. Please submit a site plan on one sheet that meets the requirements show in in the Full plot plan (because the shed had utilities) shown at example at https://www.tucsonaz.gov/Departments/Planning-Development-Services/Permits/Plan-Examples/Site-Plan-Examples . Some, but not all information to include on the site plan are: Name of owner and property address ` Zoning : R-2 Special Zoning Overlays: Airport Height Overlay Zone 3 & Davis Monthan AFB Noise Control District A Basic Project Description 10’ X 10’ Shed Demo Scale such as an Engineers Scale North Arrow All property lines and their dimensions The legal lot description is Citation Park Lot 159. Here is the link to the subdivision plat: https://gis.pima.gov/maps/subdiv/select.cfm?null=&bkpg=14039 Square footage of the lot: Approx 5116 sf according to Pima County GIS data. Location of all structures and distance between each other and their nearest property line. Adjacent street names. Lot coverage – square footage of all enclosed structures and all vehicle use areas divided by the lot’s square footage. Show utilities running to the shed 2. Additional comments may be forthcoming depending on responses to zoning review comments and plans submitted for the next review. If you have any questions about this transmittal, please contact Roxanne Johnston at roxanne.johnston@tucsonaz.gov . |
||
| 05/20/2026 | PDSD Application Completeness Express | REVIEW COMPLETED |