Permit Number: TC-COM-1225-02358
Parcel: 127052180

Address:
4864 E BAKER ST

Review Status: Requires Resubmit

Review Details: COMMERCIAL REVIEW - FULL v.1

Permit Number - TC-COM-1225-02358
Review Name: COMMERCIAL REVIEW - FULL v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
01/14/2026 Outdoor Lighting Standard NOT REQUIRED No modifications to the outdoor lighting.
01/09/2026 Site Engineering Standard NOT REQUIRED
01/29/2026 Bldg Permits - Post Review Express PENDING ASSIGNMENT
01/29/2026 Commercial Building Standard REQUIRES RESUBMIT Please submit your revised documents and provide a letter with a written response letter addressing each of the comments indicating how the Review comments were resolved. Additionally, please submit complete copies of all permit documents (i.e. plans, calculations, reports, etc.) even if they have not been changed. Please note the submittal was incomplete and the plan review was conducted using the information presented. The subsequent review could generate more comments after original comments have been addressed.

Please contact me if you have any questions about the below comments.
I can be reached at email mark.masek@tucsonaz.gov

1. Please provide some historical information regarding this building and please explain why this building dose not have a C of O.
2. The space at the rear of the Assembly space appears to not be assigned an occupant load, please explain why. IBC 1004.5 It would appear the occupant load would exceed 50 and require panic hardware. IBC 1010.1.10


Please contact me if you have any questions about the above comments.
Mark Masek
Plans Examiner – Building Safety
Planning and Development Services | City of Tucson
main 520.837.4994
email mark.masek@tucsonaz.gov
01/15/2026 Commercial Electrical Standard REQUIRES RESUBMIT Commercial Electrical Review TC-COM-1225-02358 (4868 E BAKER ST TUCSON, AZ 85711)
Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide updated Plans/calculations and a written response Letter to each of the notated items indicating action taken. Resubmitted plans that do not contain a written response Letter addressing each of the notated items indicating action taken, may be delayed until response letter is received.
Code reference, 2018 International Building Code (IBC), 2017 National Electrical Code (NEC).

1. Provide an as-built electrical floor plan showing all existing electrical outlets, lights, receptacles and electrical panels. IBC 107.1.

Contact Jeremy Hamblin with any questions: Jeremy.hamblin@tucsonaz.gov
01/27/2026 Site Zoning Standard REQUIRES RESUBMIT PDSD TRANSMITTAL

FROM:
Bobby Parsons
Zoning Section Review

PROJECT:
TC-COM-1225-02358
4868 E. Baker St. Tucson, AZ 85711
Replacement CofO for Existing Church (1st Review)

TRANSMITTAL DATE: 1/27/2026

This site is located in the R-2 zone (UDC 4.7.9). Religious Use is an allowed use in this zone (UDC Table 4.8-2).

Comments: Please resubmit revised drawings along with a detailed response letter which states how all Zoning Review Section comments were addressed.

1. Comment: The description listed for this permit is “replacement certificate of occupancy for existing church”. Can you please provide the existing CofO permit number as this description states one was previously issued.
2. Comment: As this site is made up of two (2) parcels, 127052180 and 127052190, a lot combination or a recorded covenant will be required. Either provide the approved lot combination request form or a recorded Covenant Regarding Development and Use of Real Property with your next submittal. Contact Pima County for the Combo Request. The Covenant can be found at: https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/submission-documents/covenant-regarding-development-and-use-of-real-property-udc-with-release.pdf.
3. Comment: The site plan calls out 2 sheds and a future shade ramada. Aerial imagery does not show the shed behind the building, and a permit was not found for either of the sheds included on your site plan. As this is a CofO request, please remove the sheds and the future shade ramada from the site plan.
4. Additional comments may be forthcoming depending on responses to zoning review comments and plans submitted.

If you have any questions about this transmittal, please contact Bobby Parsons at Robert.Parsons@tucsonaz.gov.
01/27/2026 Water - PDSD Standard REQUIRES RESUBMIT Provide the size of the water meter serving the building
01/27/2026 Commercial Mechanical Standard REVIEW COMPLETED
01/27/2026 Commercial Plumbing Standard REVIEW COMPLETED
01/26/2026 Fire New Construction Standard REVIEW COMPLETED
01/05/2026 PDSD Application Completeness Express REVIEW COMPLETED