Permit Review Detail
Review Status: In Review
Review Details: COMMERCIAL REVIEW - FULL v.1
Permit Number - TC-COM-1225-02356
Review Name: COMMERCIAL REVIEW - FULL v.1
Review Status: In Review
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 01/14/2026 | Outdoor Lighting Standard | NOT REQUIRED | No modifications to the outdoor lighting. | ||
| N/A | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| N/A | Commercial Building Standard | PENDING ASSIGNMENT | |||
| N/A | Commercial Mechanical Standard | PENDING ASSIGNMENT | |||
| N/A | Commercial Plumbing Standard | PENDING ASSIGNMENT | |||
| N/A | Fire New Construction Standard | PENDING ASSIGNMENT | |||
| N/A | Site Zoning Standard | PENDING ASSIGNMENT | |||
| N/A | Water - PDSD Standard | PENDING ASSIGNMENT | |||
| 01/15/2026 | Commercial Electrical Standard | REQUIRES RESUBMIT | Commercial Electrical Review TC-COM-1225-02356 (2595 N FAIRVIEW AV TUCSON, AZ 85705) Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide updated Plans/calculations and a written response Letter to each of the notated items indicating action taken. Resubmitted plans that do not contain a written response Letter addressing each of the notated items indicating action taken, may be delayed until response letter is received. Code reference, 2018 International Building Code (IBC), 2017 National Electrical Code (NEC). 1. Provide a complete site plan. Indicate the location and size of buildings, utility meters and lines supporting the alterations, IBC 106.1.1. Show all utility lines. 2. Provide an updated Electrical plan showing compliance with the currently adopted electrical codes, 2017 NEC. 3. Provide or show compliance with NEC article 500, including any Hazardous Classification zones and wiring methods. Contact Jeremy Hamblin with any questions: Jeremy.hamblin@tucsonaz.gov |
||
| 01/16/2026 | Site Engineering Standard | REQUIRES RESUBMIT | Site Engineering Review TC-COM-1225-02356 2595 N FAIRVIEW AV Summary: 1000-gallon aboveground propane tank and self-contained dispenser Site Engineering comments are as follows: 1. This permit submittal requires a complete site plan in compliance with this check list: Commercial Submittal Requirements “A fully dimensioned site plan (not an aerial photograph) shall show project address including suite numbers and legal description. All easements with dimensions, lot area, north arrow, and scale. Location of all property lines, structure to property line setback dimensions (existing and proposed), proposed and existing utility meters, public sewer connections, sump pumps, back flow devices, and fire hydrant locations. Please provide street names for all adjacent streets, a fully dimensioned parking plan including tabulation of existing, proposed and required parking spaces. Locations of all buildings/structures on adjacent property within 10 feet of property Page 3 of 4 Revised July 12, 2023 line, including location and dimensions of all walkways and driveways related to ADA considerations. Submitted plans must be in compliance with the approved entitlements for the project and any conditions of approval.” To re-submit, visit the Tucson Development Center Online at: https://tdc-online.tucsonaz.gov/#/home The instructions for resubmittal can be found at: Revisions and Resubmittals Engineering Associate: Ryan Insalaco ryan.insalaco@tucsonaz.gov |
||
| 01/05/2026 | PDSD Application Completeness Express | REVIEW COMPLETED | Proposed work based on original permit T10BU01390 |