Permit Review Detail
Review Status: Requires Resubmit
Review Details: COMMERCIAL REVIEW - FULL v.2
Permit Number - TC-COM-1225-02344
Review Name: COMMERCIAL REVIEW - FULL v.2
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 03/24/2026 | Commercial Building Standard | APPROVED | |||
| 03/10/2026 | Commercial Electrical Standard | APPROVED | |||
| 03/10/2026 | Outdoor Lighting Standard | APPROVED | |||
| 03/24/2026 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 03/24/2026 | Commercial Mechanical Standard | REQUIRES RESUBMIT | The proposed stormwater downspouts terminate at the paved vehicle storage area. Condensate drains may not terminate over a roof drain or gutter unless the roof drain or gutter terminates at or below grade in an area capable of absorbing the condensate flow without surface drainage. Reference: Section 307.2.1, IMC 2018, as amended by the City of Tucson. [Initial comment: Condensate drains shall be terminated at an approved disposal location (i.e. a splash block on the roof is not an approved location). Reference: Section 307.2.1, IMC 2018, as amended by the City of Tucson.] If you have any questions about this review comment, I can be reached at Robert.Sherry@tucsonaz.gov. |
||
| 03/24/2026 | Commercial Plumbing Standard | REQUIRES RESUBMIT | The “overflow opening” in the conductor head does not comply with Section 1108, Secondary (emergency overflow) drains or scupper s, IPC 2018. A secondary scupper is: 1. completely separate from the primary scupper 2. it has a discharge that is separate from the primary scupper 3. it has the capacity to prevent ponding on the roof if the primary scupper is blocked for any reason 4. the discharge is above grade and visible to building occupants. [Initial comment: Provide secondary (overflow) roof drainage. Reference: Sections 1108.1, 1108.2 and 1108.3, IPC 2018.] If you have any questions about this review comment, I can be reached at Robert.Sherry@tucsonaz.gov. |
||
| 03/17/2026 | Site Engineering Standard | REQUIRES RESUBMIT | Permit Activity Number: TC-COM-1225-02344 (2nd Review) Project: New Masonry Building -12 bay automotive service for KIA Royal dealership Location: 4333 E SPEEDWAY BL Review Date: 3/17/2026 Reviewer: Marco Contreras – Engineering Associate - Site Engineering Related Cases: *This plan has been reviewed for compliance with applicable development criteria in the City of Tucson Unified Development Code (UDC) Administrative Manual (AM) Section 2-6 and Technical Standards Manual (TSM) Section for waste management, Pedestrian Access, Hydrology -Retention/Detention Requirements, and all site standard code. * City of Tucson Code: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Codes Floodplain Code: https://codelibrary.amlegal.com/codes/tucson/latest/tucson_az/0-0-0-19333 Drainage Manual Link: https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/engineering-code/cot-drainage-manual-searchable.pdf Design standards for Stormwater Detention and Retention Link: https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/engineering-code/updated-retention-detention-manual.pdf Site Engineering Review Comments: 1. After reviewing the submitted plan set and the associated Development Package TD-DEV-0523-00248, it appears the plan sets do not match up. a. Revise the plan set to include the most current (Up-to-date) site plans that were approved under TD-DEV-1225-00306. It appears the currently shown site plans are from previous (Unapproved) versions from the DP process. Revise accordingly. If you have any questions or concerns, please contact Marco Contreras at Marco.contreras@tucsonaz.gov |
||
| 03/24/2026 | Site Zoning Standard | REQUIRES RESUBMIT | PDSD TRANSMITTAL FROM: Bobby Parsons Zoning Section Review PROJECT: TC-COM-1225-02344 - TD-DEV-1225-00306 4333 E. Speedway Blvd. Tucson, AZ 85712 New Masonry 12 Bay Automotive Service Building (1st Review) TRANSMITTAL DATE: 3/24/2026 This site is located in the C-2 zone (UDC 4.7.21). Comments: Please resubmit revised drawings along with a detailed response letter which states how all Zoning Review Section comments were addressed. 1. Comment: The associated Development Package (DP) TD-DEV-1225-00306 lists 6,700 sf for the proposed building #5 however these plans list the size of building #5 as 7,027 sf. The building plans, including square footage and height, need to match what was approved in the DP. Please either revise your DP to match what is being proposed in this building permit or update your building square footage in this permit to reflect what was approved in TD-DEV-1225-00306. 2. Comment: Additional comments may be forthcoming depending on responses to zoning review comments and plans submitted. If you have any questions about this transmittal, please contact Bobby Parsons at Robert.Parsons@tucsonaz.gov. |
||
| 03/24/2026 | Water - PDSD Standard | REQUIRES RESUBMIT | Tucson Water limits a 1-1/2” meter to a maximum demand of 100 GPM. Your calculations show a demand of 122 GPM. Provide a letter from Tucson Water confirming that the use of a 1-1/2” water meter will be allowed for this project or install a 2” water meter. [Initial comment: Verify the size of the water meter serving this building, the size of the backflow preventer associated with the water meter, and the total water demand served by the water meter. Reference: Section 107.2.1, IBC 2018.] If you have any questions about this review comment, I can be reached at Robert.Sherry@tucsonaz.gov. |
||
| 03/03/2026 | PDSD Application Completeness Express | REVIEW COMPLETED |