Permit Review Detail
Review Status: Requires Resubmit
Review Details: COMMERCIAL REVIEW - FULL v.3
Permit Number - TC-COM-1225-02341
Review Name: COMMERCIAL REVIEW - FULL v.3
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 04/15/2026 | Commercial Building Standard | APPROVED | |||
| 04/20/2026 | Commercial Mechanical Standard | APPROVED | |||
| 06/04/2026 | Entitlements Standard | APPROVED | TP-MOD-0226-000023 approved | ||
| 06/04/2026 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 04/20/2026 | Commercial Plumbing Standard | REQUIRES RESUBMIT | Comment not addressed. [Initial comment: For what uses will the 3-compartment sink be used? If the 3-compartment sink is used only for washing, rinsing, and sanitizing utensils used for food service, the sink shall drain indirectly to the grease interceptor with an air gap or an air break. If, however, the 3-compartment sink is also used for the preparation of food items, separate indirect waste pipes shall be provided for each compartment to protect against cross-contamination or fouling and each indirect drain shall terminate with an air gap. Reference: Sections 801.2, 802.1.1, and 802.1.7, IPC 2018.] If you have any questions about this review comment, I can be reached at Robert.Sherry@tucsonaz.gov. |
||
| 04/20/2026 | Site Zoning Standard | REQUIRES RESUBMIT | 1. COMMENT: The associated PAD amendment (TP-MOD-0226-000023) and development package (TD-DEV-0226-00037) for this site must first be approved before the building permit can receive final Site Zoning approval. Contact Fernando Garcia, Lead Planner, Site Zoning at fernando.garcia2@tucsonaz.gov. |
||
| 04/20/2026 | Water - PDSD Standard | REQUIRES RESUBMIT | Comment not addressed. [Initial comment: Reduced pressure backflow prevention assemblies are required at the water meter for multi-use commercial buildings. Reference: Chapter XXVII, Article V, Section 27-72, the Tucson Code, https://www.tucsonaz.gov/files/sharedassets/public/city-services/tucson-water/water-quality/documents/backflow-ordinance.pdf] If you have any questions about this review comment, I can be reached at Robert.Sherry@tucsonaz.gov. |
||
| 04/03/2026 | PDSD Application Completeness Express | REVIEW COMPLETED |