| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 05/04/2026 | Commercial Building Standard | APPROVED | |||
| 05/04/2026 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 04/30/2026 | Commercial Plumbing Standard | REQUIRES RESUBMIT | The roof drain calculations addressed the primary roof drainage but did not address the secondary drainage, the overflow weirs. [Initial comment: Provide calculations to show that the four overflow weirs have been designed to accommodate a 100-year rainfall rate of 3-inches per hour, like the primary downspouts. Reference: Sections 1108.1 and 1108 3, IPC 2018.] If you have any questions about this review comment, I can be reached at Robert.Sherry@tucsonaz.gov |
||
| 04/27/2026 | Site Engineering Standard | REQUIRES RESUBMIT | Permit: TC-COM-1225-02323 – Frys Fuel Canopy Location: 9440 E BROADWAY BL Review Date: 4/27/2026 This plan has been reviewed for compliance with applicable development criteria in the City of Tucson Unified Development Code (UDC) Administrative Manual (AM) Section 2-06 and Technical Manual (TM) Section for waste management, Pedestrian Access, Hydrology -Retention/Detention Requirements, and all site standard code. Drainage Manual Link: https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/engineering-code/cot-drainage… Design standards for Stormwater Detention and Retention Link: https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/engineering-code/updated-rete… Overall, for application submittal requirements, see Administrative Manual Section 2-06 Site Engineering: 1. In accordance with the final plat for Halcyon Acres Block 1 General Note #5, a floodplain use per final plat will be required to be submitted and approved. The FPU permit is a separate permit that can be submitted for within the “sub-records” tab of this commercial permit on TDC online. a. Site Engineering will be unable to approve permit TC-COM-0226-00277 until the associated FPU permit is approved. It is recommended that the FPU permit process be started and achieve approval and issuance prior to the resubmission of this permit to ensure no project delays and review overlap. 2. Site Engineering has reviewed the building plans for compliance with development package TD-DEV-0225-00061. Until the development package is approved by all reviewers, site engineering will be unable to approve permit TC-COM-1225-02323. If you have any questions or concerns, please contact Joe Macaulay at: Joe.Macaulay@tucsonaz.gov |
||
| 05/01/2026 | Site Zoning Standard | REQUIRES RESUBMIT | PDSD TRANSMITTAL FROM: Bobby Parsons Zoning Section Review PROJECT: TC-COM-1225-02323 - TD-DEV-0225-00061 9440 E. Broadway Blvd. Tucson, AZ 85710 New Fry’s Fuel Canopy (2nd Review) TRANSMITTAL DATE: 5/1/2026 The site is located in C-1 zone (UDC 4.7.20) and SR zone (4.7.4). General Merchandise Sales is a permitted use in the C-1 zone subject to Use Specific Standard 4.9.9.B.3 and 4.9.13.O (UDC Table 4.8-3). Comments: Please resubmit revised drawings along with a detailed response letter which states how all Zoning Review Section comments were addressed. 1. Comment: Zoning has conducted a cursory review of the building permit plan set and while it appears the site plan is consistent with the associated Development Package (DP), Site Zoning cannot approve this building permit until TD-DEV-0225-00061 has been approved by all reviewers. 2. Comment: Additional comments may be forthcoming depending on responses to zoning review comments and plans submitted. If you have any questions about this transmittal, please contact Bobby Parsons at Robert.Parsons@tucsonaz.gov. |
||
| 04/10/2026 | PDSD Application Completeness Express | REVIEW COMPLETED |