Permit Number: TC-COM-1225-02306
Parcel: 134091680

Review Status: Requires Resubmit

Review Details: COMMERCIAL REVIEW - FULL v.3

Permit Number - TC-COM-1225-02306
Review Name: COMMERCIAL REVIEW - FULL v.3
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
08/03/2026 Commercial Building Standard APPROVED
07/14/2026 Commercial Electrical Standard APPROVED
07/14/2026 Outdoor Lighting Standard NOT REQUIRED No modifications to the outdoor lighting.
08/03/2026 Bldg Permits - Post Review Express PENDING ASSIGNMENT
07/28/2026 Commercial Mechanical Standard REQUIRES RESUBMIT The heating and cooling load for Unit 1 (FC-1 and CU-1) is not shown. [Initial comment: Provide heating and cooling load calculations that justify the capacities of the heating and cooling equipment specified for Unit 1 (FC-1 and CU-1). Reference: Sections R403.7and R503.1.2, IECC 2018 as amended by the City of Tucson.]
If you have any questions about this review comment, I can be reached at Robert.Sherry@tucsonaz.gov
07/28/2026 Commercial Plumbing Standard REQUIRES RESUBMIT Coordinate the drawings. A new 3” building drain connects to an existing 3” building drain on risers 5, 6, and 7/P3.1, but on P2.1, keynote #2 calls for the new 3” building drain to connect to an existing 4” building drain. [Initial comment: Verify the size of the existing first floor building drains shown in riser diagram, 6/P3.1. The plan drawings show 4” but the riser diagrams show 3” existing building drains. Reference: Section 107.2.1, IBC 2018.]

If you have any questions about this review comment, I can be reached at Robert.Sherry@tucsonaz.gov
07/09/2026 Addressing Validation REVIEW COMPLETED
07/09/2026 PDSD Application Completeness Express REVIEW COMPLETED