Permit Number: TC-COM-1225-02288
Parcel: 10820051K

Review Status: Requires Resubmit

Review Details: COMMERCIAL REVIEW - FULL v.1

Permit Number - TC-COM-1225-02288
Review Name: COMMERCIAL REVIEW - FULL v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
01/02/2026 Commercial Electrical Standard APPROVED
01/02/2026 Outdoor Lighting Standard NOT REQUIRED No modifications to the outdoor lighting.
12/22/2025 Site Engineering Standard NOT REQUIRED
01/13/2026 Site Zoning Standard NOT REQUIRED
01/15/2026 Bldg Permits - Post Review Express PENDING ASSIGNMENT
01/15/2026 Commercial Building Standard REQUIRES RESUBMIT ACTIVITY NO. TC-COM-1225-02288
ADDRESS: (4016 N 1ST AV Unit:UNIT 100 TUCSON, AZ 85719)
Submit your revised drawings along with a detailed response letter, which states how all Building Review Section comments were addressed. Please paste the review comment individually and enter your response directly below it. Please do this for every comment. Review will not proceed without the response letter. The submitted documents were incomplete and a thorough plan review could not be performed. Please be aware, new comments may arise with the next review. Should the above not followed, it may delay your approval. Additionally, please submit complete copies of all permit documents (i.e. plans, calculations, reports, etc.) even if they have not been changed.

COMMENTS:
1. SHEET A-1
a. SHOP DRAWINGS
i. The drawings and verbiages are pixelated and not readable.
1. Please submit clear drawings and specification information.
ii. Resubmit the corrected set.
b. FLOOR PLAN
i. Clear aisle dimension between corner of freezer to the katicorner equipment.
1. Code required dimension is not met.
2. The clear dimension with occupant load of 50 or more is not less than 44 inches per IBC Table 1020.3.
3. Please correct this discrepancy.
2. ARCHITECT SEAL
a. Seal is showing blank areas where the Architect Discipline and the State that issued the license.
b. Please affix the proper seal/signature/date.
3. Please resubmit.
Should you have any questions about these comments, I can be reached at Justin.Eder@tucsonaz.gov or 520-837-4976.
01/14/2026 Commercial Mechanical Standard REQUIRES RESUBMIT ACTIVITY NO. TC-COM-1225-02288
ADDRESS/PARCEL: (4016 N 1ST AV Unit:UNIT 100 TUCSON, AZ 85719)

Submit your revised drawings along with a detailed response letter, which states how all comments were addressed. Review will not proceed without the response letter. The submitted documents were incomplete and a thorough plan review could not be performed. Please be aware, new comments may arise with the next review.

COMMENTS:
1. Please show the walk-in cooler/freezer meets the efficiency requirements of Section C403.10.2.1, IECC 2018.
2. Architect Seal on cover sheet.
a. Per the State of Arizona Board of Technical Registration Arizona Administrative Code R4-30-303 and R4-30-304 before sealing any work, Registrant shall secure and use a seal for a branch in which registration has been granted. A permanently legible imprint of the registrant’s seal, signature, date signed shall appear and must bear the branch phrase applicable to the registrant such as Agriculture/Architectural/Chemical/Structural/Civil/Electrical/Environmental/Fire Protection/Geological/Mechanical/Land Surveyor, etc.
01/14/2026 Commercial Plumbing Standard REQUIRES RESUBMIT ACTIVITY NO. TC-COM-1225-02288
ADDRESS/PARCEL: (4016 N 1ST AV Unit:UNIT 100 TUCSON, AZ 85719)

Submit your revised drawings along with a detailed response letter, which states how all comments were addressed. Review will not proceed without the response letter. The submitted documents were incomplete and a thorough plan review could not be performed. Please be aware, new comments may arise with the next review.

COMMENTS:
1. Please clarify whether the existing prep sink is being removed or relocated. The proposed walk-in freezer appears to be located in this area. This is based on the floor plan stamped by Vincent Catalano.
2. It appears the handwashing sink has been relocated adjacent to the three-door reach-in refrigerator. Please clarify and revise the plans as necessary.
01/13/2026 Fire New Construction Standard REVIEW COMPLETED
12/22/2025 PDSD Application Completeness Express REVIEW COMPLETED