Permit Review Detail
Review Status: Requires Resubmit
Review Details: COMMERCIAL REVIEW - FULL v.2
Permit Number - TC-COM-1225-02277
Review Name: COMMERCIAL REVIEW - FULL v.2
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 03/02/2026 | Commercial Building Standard | APPROVED | REMINDER: please do not forget to submit a permit for the demolition of the existing structure. | ||
| 02/10/2026 | Commercial Electrical Standard | APPROVED | |||
| 02/26/2026 | Water - PDSD Standard | APPROVED | |||
| 03/02/2026 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 02/26/2026 | Commercial Mechanical Standard | REQUIRES RESUBMIT | ACTIVITY NO. TC-COM-1225-02277 ADDRESS/PARCEL: 9015 E TANQUE VERDE RD TUCSON, AZ 85749 Submit your revised drawings along with a detailed response letter, which states how all comments were addressed. Review will not proceed without the response letter. The submitted documents were incomplete and a thorough plan review could not be performed. Please be aware, new comments may arise with the next review. If you have any questions about these review comments, I can be reached at Sean.Severson@tucsonaz.gov COMMENTS: 1. Previous comment not addressed. [Show that the cold vault, the walk-in cooler and the walk-in freezer meet the construction requirements of Section C403.10.2, IECC 2018.] 2. Previous comment not addressed. [Show that the cold vault, the walk-in cooler and the walk-in freezer meet the efficiency requirements of Section C403.10.2.1, IECC 2018.] |
||
| 02/26/2026 | Commercial Plumbing Standard | REQUIRES RESUBMIT | ACTIVITY NO. TC-COM-1225-02277 ADDRESS/PARCEL: 9015 E TANQUE VERDE RD TUCSON, AZ 85749 Submit your revised drawings along with a detailed response letter, which states how all comments were addressed. Review will not proceed without the response letter. The submitted documents were incomplete and a thorough plan review could not be performed. Please be aware, new comments may arise with the next review. If you have any questions about these review comments, I can be reached at Sean.Severson@tucsonaz.gov COMMENTS: 1. Previous comment not addressed [Revise the minimum width of the two primary roof scuppers as shown on detail 9/A8.3 to 12.6”. Reference: Sections 1106.5 and 1108.3, IPC 2018.] a. Alternatively, the rainfall rate used in the roof drain calculations on Sheet P1.1 can be updated to 3 inches per hour, which is the typical rate for Tucson. After recalculating the GPM and minimum drain size, the existing scuppers called out should meet the minimum requirements. |
||
| 02/10/2026 | Outdoor Lighting Standard | REQUIRES RESUBMIT | Outdoor Lighting Review TC-COM-1225-02277 (9015 E TANQUE VERDE RD TUCSON, AZ 85749) 2nd Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide updated Plans/calculations and a written response Letter to each of the notated items indicating action taken. Resubmitted plans that do not contain a written response Letter addressing each of the notated items indicating action taken, may be delayed until response letter is received. Code reference, 2018 International Building Code (IBC), 2017 National Electrical Code (NEC), 2012 Outdoor Lighting Code (OLC). Outdoor Lighting Review: https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/building-code/2012_outdoor_lighting_code_.pdf Contact Jeremy Hamblin with any questions: Jeremy.hamblin@tucsonaz.gov 1. The LED string and flex lights are not considered full cutoff per definition in chapter 2. The installation under canopies or overhangs or roof eaves does not provide full cutoff classification of these unshielded light fixtures. See OLC 401.2.1 sub-paragraph 4. An appeal to the building official is required to change this section for your case. 2. This site requires an outdoor lighting special inspection, OLC 106.2.1. Provide a intermediate OL Special Inspection Certificate, with parts A and B completed and sealed prior to issuance of the permit. Make a note on the plans stating that a special inspection is required. https://www.tucsonaz.gov/files/sharedassets/public/v/1/city-services/planning-development-services/documents/special_inspection_certificate_odl.pdf 3. The total unshielded lumen calculation is missing. This site, under compliance option #3 provides a total of 9,000 lumens per acre of unshielded lumens. The lumen count from fixtures L2, L3, SF, SF*, is greater than 9,000 lumens per acre. |
||
| 02/12/2026 | Site Engineering Standard | REQUIRES RESUBMIT | Permit Activity Number: TC-COM-1225-02277 (2nd Review) Project: A NEW CONVENIENCE STORE WITH ASSOCIATED FUEL SALES Location: 9015 E TANQUE VERDE RD Review Date: 2/12/2026 Reviewer: Marco Contreras – Engineering Associate - Site Engineering Site Engineering Review Comments: 1. Site Engineering has reviewed the plan set submitted. Site Engineering is unable to fully approved permit TC-COM-1225-02277 until the associated development package TD-DEV-1025-00258 is fully approved and issued. If you have any questions or concerns, please contact Marco Contreras at Marco.contreras@tucsonaz.gov |
||
| 02/27/2026 | Site Zoning Standard | REQUIRES RESUBMIT | PDSD TRANSMITTAL FROM: Bobby Parsons Zoning Section Review PROJECT: TC-COM-1225-02277 - TD-DEV-1025-00258 9015 E. Tanque Verde Rd. Tucson, AZ 85749 New Convenience Store and Associated Fuel Sales (2nd Review) TRANSMITTAL DATE: 2/27/2026 This site is in the C-1 zone (UDC 4.7.20). General Merchandise Sales (excluding large retail) is a permitted use in the zone (UDC Table 4.8-4), subject to Use Specific Standards 4.9.9.B.3 and 4.9.13.O. Comments: Please resubmit revised drawings along with a detailed response letter which states how all Zoning Review Section comments were addressed. 1. Comment: Site Zoning has reviewed the building plans for compliance with the associated Development Package (DP) TD-DEV-1025-00258. Site zoning cannot approve this permit until the DP is approved by all review agencies. 2. Comment: Please ensure the heights shown on sheet A2.1 are consistent with the heights proposed in the development package. 3. Comment: Additional comments may be forthcoming based on responses to zoning comments and plans submitted. If you have any questions about this transmittal, please contact Bobby Parsons at Robert.Parsons@tucsonaz.gov. |
||
| 02/05/2026 | PDSD Application Completeness Express | REVIEW COMPLETED |