Permit Number: TC-COM-1225-02247
Parcel: 12212048A

Review Status: Requires Resubmit

Review Details: COMMERCIAL REVIEW - FULL v.2

Permit Number - TC-COM-1225-02247
Review Name: COMMERCIAL REVIEW - FULL v.2
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
02/12/2026 Commercial Building Standard APPROVED
02/10/2026 Commercial Mechanical Standard APPROVED
02/12/2026 Bldg Permits - Post Review Express PENDING ASSIGNMENT
02/10/2026 Commercial Plumbing Standard REQUIRES RESUBMIT ACTIVITY NO. TC-COM-1225-02247
ADDRESS/PARCEL: 4373 E SPEEDWAY BL TUCSON, AZ 85712

Submit your revised drawings along with a detailed response letter, which states how all comments were addressed. Review will not proceed without the response letter. The submitted documents were incomplete and a thorough plan review could not be performed. Please be aware, new comments may arise with the next review.

If you have any questions about these review comments, I can be reached at Sean.Severson@tucsonaz.gov

COMMENTS:

1. Please show a detail on the drawing of how the drain for the waterdrop reverse osmosis unit is being installed. The Product User Manual shows a drain saddle and saddle-type fittings are prohibited. Reference: Section 707.1 (6), IPC 2018.
2. Provide accessible cleanouts in the island sink vent system to permit rodding of all portions of the vents located below the flood rim of the fixture. Reference: Section 916.3, IPC 2018.
01/23/2026 PDSD Application Completeness Express REVIEW COMPLETED