Permit Review Detail
Review Status: Requires Resubmit
Review Details: COMMERCIAL REVIEW - FULL v.1
Permit Number - TC-COM-1225-02247
Review Name: COMMERCIAL REVIEW - FULL v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 12/30/2025 | Commercial Electrical Standard | APPROVED | |||
| 01/08/2026 | Site Zoning Standard | APPROVED | |||
| 01/08/2026 | Water - PDSD Standard | APPROVED | |||
| 12/30/2025 | Outdoor Lighting Standard | NOT REQUIRED | No modifications to the outdoor lighting. | ||
| 12/17/2025 | Site Engineering Standard | NOT REQUIRED | |||
| 01/08/2026 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 01/06/2026 | Commercial Building Standard | REQUIRES RESUBMIT | Please submit your revised documents and provide a letter with a written response letter addressing each of the comments indicating how the Review comments were resolved. Please note the submittal was incomplete and the plan review was conducted using the information presented. The subsequent review could generate more comments after original comments have been addressed. 1. Please provide the structural calculations; sealed by an Arizona licensed design professional, used in the design of this project with the next submittal. IBC 107.2.7 2. Please, provide the City of Tucson Special Inspection Certificate(s) with Parts A and B completed with the next submittal. IBC 107.1 SI form link: https://www.tucsonaz.gov/files/sharedassets/public/v/1/city-services/planning-development-services/documents/special_inspection_certificate.pdf 3. Please amend the plans to indicate if the stairways are interior exit access or interior exit stairways. IBC 107.2.1 Please contact me if you have any questions about these comments. Mark Masek Plans Examiner – Building Safety Planning and Development Services | City of Tucson main 520.837.4994 email mark.masek@tucsonaz.gov |
||
| 01/08/2026 | Commercial Mechanical Standard | REQUIRES RESUBMIT | Smoke detectors shall be located upstream of any outside air connections. Reference: Section 606.2.1, IMC 2018. | ||
| 01/08/2026 | Commercial Plumbing Standard | REQUIRES RESUBMIT | 1. Show how the drain for the Waterdrop reverse osmosis unit is to be installed. Saddle-type fittings are prohibited. Reference: Section 707.1 (6), IPC 2018. 2. Explain how the trap for sink S-1 has been vented in accordance with one of the methods shown in the IPC. Reference: Sections 901.2.1 and 916.3, IPC 2018. |
||
| 01/07/2026 | Fire New Construction Standard | REVIEW COMPLETED | |||
| 12/16/2025 | PDSD Application Completeness Express | REVIEW COMPLETED |