Review Status: Requires Resubmit

Review Details: COMMERCIAL REVIEW - FULL v.1

Permit Number - TC-COM-1225-02245
Review Name: COMMERCIAL REVIEW - FULL v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
12/30/2025 Commercial Electrical Standard APPROVED
01/07/2026 Commercial Mechanical Standard APPROVED
01/07/2026 Site Zoning Standard APPROVED
01/07/2026 Water - PDSD Standard APPROVED
12/18/2025 Outdoor Lighting Standard NOT REQUIRED No modifications to the outdoor lighting.
12/17/2025 Site Engineering Standard NOT REQUIRED
01/07/2026 Bldg Permits - Post Review Express PENDING ASSIGNMENT
01/05/2026 Commercial Building Standard REQUIRES RESUBMIT Please submit your revised documents and provide a letter with a written response letter addressing each of the comments indicating how the Review comments were resolved. Additionally, please submit complete copies of all permit documents (i.e. plans, calculations, reports, etc.) even if they have not been changed. Please note the submittal was incomplete and the plan review was conducted using the information presented. The subsequent review could generate more comments after original comments have been addressed.
1. Please provide the following means of egress/number of plumbing fixtures calculation information
A. The total number of occupants for the story or floor is shown. IBC 107.2.3
B. The number of occupants is shown for every room and space. IBC 107.2.3
C. The occupant load factor and area are shown for every room and space. IBC 1004.5
D. The occupant load factor used reflects the use/function of the space. IBC 1004.5
For example:
The Studio could have 22 occupants with an occupant load factor of 50 sf per occupant
The Lobby could have 15 occupants with an occupant load factor of 15 sf per occupant.
The Locker area could have 4 occupants with an occupant load factor of 50 sf per occupant
The Private Training area could have 4 occupants with an occupant load factor of 50sf per occupant.
This would result in approximately 45 occupants with only one exit required.
2. Please amend the plans to specify the interior floor finishes and provide the testing agency approval report and number, flame spread and smoke development ratings. IBC 804.1
3. Please amend the Plumbing fixture load table on the plans to reflect the occupancy being used. For example, a B occupancy would require a ratio of 1 water closet for each 25 male and female occupants and 1 lavatory for each 25 male and female 40 occupants IBC Table 2902.1
4. Please amend the plans to update the plumbing fixture calculation to reflect the number of occupants and the number of restrooms matches the requirements of IBC Table 2902.1. IBC 2902.1, IBC Table 2902.1, IPC 403 For example, 45 occupants and a B occupancy would require 2 toilet rooms, one for each sex.
5. Please submit an appeal to the building official with a justification for a reduction in the number of required restrooms if one uni-sex restroom is desired.

Please contact me if you have any questions about these comments.
Mark Masek
Plans Examiner – Building Safety
Planning and Development Services | City of Tucson
main 520.837.4994
email mark.masek@tucsonaz.gov
01/07/2026 Commercial Plumbing Standard REQUIRES RESUBMIT Provide a direct connection to the building drainage system for all plumbing fixtures except as allowed by Chapter 8, IPC 2018 (i.e., the bottle filler must be directly wasted). See Section 712, IPC 2018. Reference: Section 301.3, IPC 2018.
01/06/2026 Fire New Construction Standard REQUIRES RESUBMIT Resolve building review comments.
Questions: patricia.shelton@tucsonaz.gov
12/16/2025 PDSD Application Completeness Express REVIEW COMPLETED