Permit Review Detail
Review Status: In Review
Review Details: COMMERCIAL REVIEW - FULL v.1
Permit Number - TC-COM-1225-02221
Review Name: COMMERCIAL REVIEW - FULL v.1
Review Status: In Review
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 12/18/2025 | Outdoor Lighting Standard | APPROVED | Outdoor Lighting approved under Main Permit TC-COM-1125-02143. | ||
| N/A | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| N/A | Commercial Building Standard | PENDING ASSIGNMENT | |||
| N/A | Commercial Electrical Standard | PENDING ASSIGNMENT | |||
| 01/13/2026 | Fire New Construction Standard | REQUIRES RESUBMIT | 1. Sheet T1.01, deferred submittals. You list fire sprinklers twice. Separate permits will be required for fire sprinklers, fire alarm, fire service underground, and emergency responder communication enhancement system if needed. Signals for ERCES shall be tested by PCWIN and reports provided to TFD. 2. Sheet T1.01, applicable codes. Please remove the NWFD amendments. This is not NWFD district. 3. Sheet T1.01, development data. You list the covered parking as NS, non-sprinklered. Is this referring to the S2 parking garage? S2 parking garages are required to have fire sprinklers per IFC 2024, 903.2.10. 4. Will this building have a fire pump room? If so, it shall meet all the requirements for fire pump rooms, IBC 902. Includes sizing, access, environment, lighting. Also IBC 913 for separation and other requirements. NFPA 20 for floor drain requirements. 5. Two way communication required per IBC 1009.8 at each elevator landing. Please add note. 6. IBC 1011.12. Stairway to roof required per this section. Could not locate on your drawings. john.vincent@tucsonaz.gov 5203495581 | ||
| 12/19/2025 | Historic | REQUIRES RESUBMIT | See comments provided under the main permit for this project: TC-COM-1125-02143. Historic Review is required under Ordinance No. 11933 (related to Rezoning case C9-19-21). | ||
| 12/16/2025 | Site Engineering Standard | REQUIRES RESUBMIT | Permit: TC-COM-1225-02221 Location: 375 S STONE AV Review Date: 12/16/2025 Site Engineering Comments: 1. Site Engineering is unable to review and approve permit TC-COM-1125-02221 until the associated Development Package TD-DEV-1025-00276 is reviewed and approved by all reviewers. If you have any questions or concerns, please contact Marco Contreras Marco.contreras@tucsonaz.gov |
||
| 01/07/2026 | Site Zoning Standard | REQUIRES RESUBMIT | PDSD TRANSMITTAL FROM: Bobby Parsons Zoning Section Review PROJECT: TC-COM-1225-02221 - TD-DEV-1025-00276 375 S. Stone Ave. Tucson, AZ 85701 New South Carport (1st Review) TRANSMITTAL DATE: 1/7/2026 The site is located in C-3 zone (UDC 4.7.22). Multifamily is a permitted use in this zone. Comments: Please resubmit revised drawings along with a detailed response letter which states how all Zoning Review Section comments were addressed. 1. Comment: Zoning has conducted a cursory review of the building permit plan set and while it appears the site plan is consistent with the associated Development Package (DP), Site Zoning cannot approve this building permit until the associated DP (TD-DEV-1025-00276) has been approved by all reviewers including Historic. 2. Comment: Additional comments may be forthcoming depending on responses to zoning review comments and plans submitted. If you have any questions about this transmittal, please contact Bobby Parsons at Robert.Parsons@tucsonaz.gov. |
||
| 12/16/2025 | PDSD Application Completeness Express | REVIEW COMPLETED | Shared bluebeam in TC-COM-1125-02143 |