Permit Review Detail
Review Status: Requires Resubmit
Review Details: COMMERCIAL REVIEW - LIMITED v.4
Permit Number - TC-COM-1225-02217
Review Name: COMMERCIAL REVIEW - LIMITED v.4
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 03/16/2026 | Commercial Building | APPROVED | |||
| 03/03/2026 | Outdoor Lighting | NOT REQUIRED | No modifications tot he outdoor lighting. | ||
| 03/16/2026 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 03/03/2026 | Commercial Electrical | REQUIRES RESUBMIT | Commercial Electrical Review TC-COM-1225-02217 (3350 E GRANT RD TUCSON, AZ 85716) Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide updated Plans/calculations and a written response Letter to each of the notated items indicating action taken. Resubmitted plans that do not contain a written response Letter addressing each of the notated items indicating action taken, may be delayed until response letter is received. Code reference, 2024 International Building Code (IBC), 2023 National Electrical Code (NEC). Contact Jeremy Hamblin with any questions: Jeremy.hamblin@tucsonaz.gov Electrical Review: 1. The Electrical Engineer’s seal is missing from all electrical sheets. Please resubmit and include the required EOR’s seal for the electrical design, including the updated grounding and bonding from the previous comments. 2. Provide a Grounding Electrode System at the detached structure per NEC 690.47. 3. Show the Grounding Conductor’s connection at the modules, mounting and metal support structure. 4. Show grounding details for the mounting equipment and metal support frame, NEC690.43. |
||
| 03/03/2026 | Site Engineering | REQUIRES RESUBMIT | Permit Activity Number: TC-COM-1225-02217 (1st Review) Project: Install 124KWDC Solar Shade Structure and connect to SES Location: 3350 E GRANT RD Review Date: 3/3/2026 Reviewer: Marco Contreras – Engineering Associate - Site Engineering Related Cases: TD-DEV-1125-00293 Site Engineering Comments: 1. After review of the plan set and comment response letter, it appears that Site Engineering comments were not addressed. It will be required that the height of the proposed canopy be shown on the plans. To review for compliance with UDC 7.4.6.E.2. It is required that the required the canopy follow the required height clearance of 15 – feet along the PAAL especially as the canopy is proposed to hang above the sites PAAL. If you have any questions or concerns, please contact Marco Contreras at Marco.contreras@tucsonaz.gov |
||
| 03/16/2026 | Site Zoning | REQUIRES RESUBMIT | PDSD TRANSMITTAL FROM: Krista Hansen Planning & Development Services Department – Zoning Review Section PROJECT: TC-COM-1225-02217 - TD-DEV-0125-00023 3350 E GRANT RD – R-2 / C-1 Solar Shade Structure TRANSMITTAL DATE: 3/16/2026 Resubmit revised drawings with a detailed response letter stating how all Zoning Review Section comments were addressed. 01. COMMENT: Dimension height of solar canopy structure. Per UDC 7.4.6.E.2, the minimum height clearance along a PAAL is 15 feet. For questions regarding Zoning comments, please contact me at: Krista.Hansen@tucsonaz.gov |
||
| 03/02/2026 | PDSD Application Completeness Express | REVIEW COMPLETED |