Review Status: Requires Resubmit

Review Details: COMMERCIAL REVIEW - FULL v.1

Permit Number - TC-COM-1225-02208
Review Name: COMMERCIAL REVIEW - FULL v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
12/26/2025 Commercial Electrical Standard APPROVED
01/06/2026 Site Zoning Standard APPROVED
01/02/2026 Water - PDSD Standard APPROVED
12/11/2025 Outdoor Lighting Standard NOT REQUIRED No modifications to the outdoor lighting.
12/10/2025 Site Engineering Standard NOT REQUIRED
01/06/2026 Bldg Permits - Post Review Express PENDING ASSIGNMENT
12/10/2025 Addressing Validation REQUIRES RESUBMIT Please include all unit numbers mentioned on site plan by submitting an address change request through permit sub-records. Here are some instructions for navigating sub-records: chrome-extension://efaidnbmnnnibpcajpcglclefindmkaj/https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/tdc-faq/new-pdfs/withdraws-and-extensions.pdf

For questions please contact Building_Official@tucsonaz.gov or Drew.Szentesy@tucsonaz.gov
01/06/2026 Commercial Building Standard REQUIRES RESUBMIT Please submit your revised documents and provide a letter with a written response letter addressing each of the comments indicating how the Review comments were resolved. Additionally, please submit complete copies of all permit documents (i.e. plans, calculations, reports, etc.) even if they have not been changed. Please note the submittal was incomplete and the plan review was conducted using the information presented. The subsequent review could generate more comments after original comments have been addressed.
1. Please amend the plans to show a wall assembly section drawing for the new frame walls to include wall coverings and connection details. IBC 107.2.1
2. Please amend the plans to indicate the power source for the water heater and dryer and if gas, provide a door communicating with the bedroom in compliance with IFGC 303.3 #5
IFGC 303.3 #5 The appliance is installed in a room or space that opens only into a bedroom or bathroom, and such room or space is used for no other purpose and is provided with a solid weather-stripped door equipped with an approved self-closing device. Combustion air shall be taken directly from the outdoors in accordance with Section 304.6.
3 Indicate the method used to attach the ½” drywall to the inside face of the slump Block wall. IBC 107.2.1
Please contact me if you have any questions about these comments.
Mark Masek
Plans Examiner – Building Safety
Planning and Development Services | City of Tucson
main 520.837.4994
email mark.masek@tucsonaz.gov
01/02/2026 Commercial Mechanical Standard REQUIRES RESUBMIT ACTIVITY NO. TC-COM-1225-02208
ADDRESS/PARCEL: (6924 E SPEEDWAY BL Unit:BLDG 1 UNIT 1 TUCSON, AZ 85710)
Submit your revised drawings along with a detailed response letter, which states how all comments were addressed. Review will not proceed without the response letter. The submitted documents were incomplete and a thorough plan review could not be performed. Please be aware, new comments may arise with the next review.

COMMENTS:

Plumbing and Mechanical
1. A new washer box is shown. Please clarify whether the washer and dryer are new or existing. Reference: IBC 2018, Section 107.2.1.
2. Existing location of water heater is unclear on the drawing. Please show the existing location of the water heater.
a. Provide a watertight pan of galvanized steel, aluminum, or other approved material under the water heater, with a drain to an approved location. Reference: IPC 2018, Section 504.7.
b. Please show where the gas piping, water piping, and venting will extend and connect to the existing systems as a result of relocating the water heater.
01/02/2026 Commercial Plumbing Standard REQUIRES RESUBMIT ACTIVITY NO. TC-COM-1225-02208
ADDRESS/PARCEL: (6924 E SPEEDWAY BL Unit:BLDG 1 UNIT 1 TUCSON, AZ 85710)
Submit your revised drawings along with a detailed response letter, which states how all comments were addressed. Review will not proceed without the response letter. The submitted documents were incomplete and a thorough plan review could not be performed. Please be aware, new comments may arise with the next review.

COMMENTS:

Plumbing and Mechanical
1. A new washer box is shown. Please clarify whether the washer and dryer are new or existing. Reference: IBC 2018, Section 107.2.1.
2. Existing location of water heater is unclear on the drawing. Please show the existing location of the water heater.
a. Provide a watertight pan of galvanized steel, aluminum, or other approved material under the water heater, with a drain to an approved location. Reference: IPC 2018, Section 504.7.
b. Please show where the gas piping, water piping, and venting will extend and connect to the existing systems as a result of relocating the water heater.
01/02/2026 Fire New Construction Standard REVIEW COMPLETED
12/10/2025 PDSD Application Completeness Express REVIEW COMPLETED