Permit Review Detail
Review Status: Requires Resubmit
Review Details: COMMERCIAL REVIEW - FULL v.2
Permit Number - TC-COM-1225-02199
Review Name: COMMERCIAL REVIEW - FULL v.2
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 02/24/2026 | Commercial Electrical Standard | APPROVED | Approval note: Provide complete compliance with the 2018 IECC for the interior lighting, including sensors and lighting controls as required. (typically COMcheck). | ||
| 03/17/2026 | Commercial Mechanical Standard | APPROVED | |||
| 02/26/2026 | Site Engineering Standard | APPROVED | |||
| 03/17/2026 | Site Zoning Standard | APPROVED | Associated DP (TD-DEV-0725-00182) has been approved. | ||
| 03/17/2026 | Water - PDSD Standard | APPROVED | |||
| 03/17/2026 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 03/17/2026 | Commercial Plumbing Standard | REQUIRES RESUBMIT | ACTIVITY NO. TC-COM-1225-02199 ADDRESS/PARCEL: 10100 E OLD VAIL RD TUCSON, AZ 85747 Submit your revised drawings along with a detailed response letter, which states how all comments were addressed. Review will not proceed without the response letter. The submitted documents were incomplete and a thorough plan review could not be performed. Please be aware, new comments may arise with the next review. If you have any questions about these review comments, I can be reached at Sean.Severson@tucsonaz.gov COMMENTS: Mechanical 1. The 3/4” gas piping branch serving the dual vat fryer on the gas distribution diagram (Sheet P100) appears to be undersized per 2018 IFGC Table 402.4(2). Also, Detail 6/P700 shows a 1” line. Please revise for consistency. 2. Previous comment not fully addressed. [ Previous comment - Condensate drains shall be terminated at an approved disposal location. Draining the condensate onto the roof deck is not an approved disposal location. Reference: Section 307.2.1, IMC 2018, as amended by the City of Tucson.] Detail 13/P700 still shows condensate draining onto roof deck because it is not clearly specified on sheet P110. Please revise Detail 13/P700 accordingly and clearly show the size, routing, and termination point of the condensate on the Sanitary Waste and Vent Plan on Sheet P110. |
||
| 02/24/2026 | Outdoor Lighting Standard | REQUIRES RESUBMIT | Outdoor Lighting Review TC-COM-1225-02199 (10100 E OLD VAIL RD TUCSON, AZ 85747) Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide updated Plans/calculations and a written response Letter to each of the notated items indicating action taken. Resubmitted plans that do not contain a written response Letter addressing each of the notated items indicating action taken, may be delayed until response letter is received. Code reference, 2018 International Building Code (IBC), 2017 National Electrical Code (NEC). Contact Jeremy Hamblin with any questions: Jeremy.hamblin@tucsonaz.gov 1. The shell permit is not yet approved, and the outdoor lighting is incomplete on the shell permit, TC-COM-1225-02185 (10100 E OLD VAIL RD TUCSON, AZ 85747). The shell permit must show all the outdoor lighting on the site, including the exterior lights placed on the building. The Outdoor Lighting review for this permit cannot be approved until the shell permit is also approved first. 2. LED strip lights, such as X9, are unshielded and must be limited to 3000 lumens per total length. |
||
| 02/24/2026 | PDSD Application Completeness Express | REVIEW COMPLETED |