Permit Number: TC-COM-1225-02164
Parcel: 14018002C

Review Status: Requires Resubmit

Review Details: COMMERCIAL REVIEW - FULL v.1

Permit Number - TC-COM-1225-02164
Review Name: COMMERCIAL REVIEW - FULL v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
12/05/2025 Site Engineering Standard NOT REQUIRED
12/29/2025 Site Zoning Standard NOT REQUIRED
12/29/2025 Bldg Permits - Post Review Express PENDING ASSIGNMENT
12/18/2025 Commercial Building Standard REQUIRES RESUBMIT Please submit your revised documents and provide a letter with a written response letter addressing each of the comments indicating how the Review comments were resolved. Please note the submittal was incomplete and the plan review was conducted using the information presented. The subsequent review could generate more comments after original comments have been addressed.
1. This is a commercial project, requiring all documents to be prepared, sealed, signed, and dated by a registered design professional. Provide complete architectural/structural plans, sealed by an Arizona Registrant. Reference: Arizona Revised Statutes 32-125, Board of Technical Registration Rules R4-30-304, 2018 IBC section 107.1, 2017 , City of Tucson Commercial Plan Submittal Requirements. https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/checklists/commercial_submittal_requirements_july2023.pdf
2. Registrant to provide a damage assessment as well as a construction repair design and drawings. Please prepare code-compliant construction drawings for this damage repair project. Please address each area of damage and repair described in the damage assessment and locate these areas on the new construction drawings. IBC 107.2.1
Please contact me if you have any questions about these comments. Mark Masek Plans Examiner – Building Safety Planning and Development Services | City of Tucson main 520.837.4994 email mark.masek@tucsonaz.gov
12/17/2025 Commercial Electrical Standard REQUIRES RESUBMIT Commercial Electrical Review TC-COM-1225-02164 (1120 E IRVINGTON RD Unit:UNIT 303 TUCSON, AZ 85714)
Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide updated Plans/calculations and a written response Letter to each of the notated items indicating action taken. Resubmitted plans that do not contain a written response Letter addressing each of the notated items indicating action taken, may be delayed until response letter is received.
Code reference, 2018 International Building Code (IBC), 2017 National Electrical Code (NEC).

1. Due to the active code Case: CE-VIO0724-02621, a complete plan-set needs to be submitted addressing all the issues listed in the code case.
2. This is a commercial project, requiring all documents to be prepared, sealed, signed, and dated by a registered design professional. Provide complete electrical plans, design, and calculations, sealed by an Arizona Registrant. Reference: Arizona Revised Statutes 32-125, Board of Technical Registration Rules R4-30-304, 2018 IBC section 107.1, 2017 NEC, City of Tucson Commercial Plan Submittal Requirements. https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/checklists/commercial_submittal_requirements_july2023.pdf
3. Show two or more 2O AMP small appliance circuits at the kitchen countertop receptacle outlets; they may also serve the breakfast room and dining room, but not other locations, [NEC 210.52(C)(1)] and [NEC 210.52(B)(1)]. GFCI protected, [NEC 210.8(A)].
4. Show receptacle outlets at each kitchen counter space wider than 12” with no point along the wall line more than 24” from a receptacle outlet, NEC 210.52(C)(1).
5. Provide protection of all interior 15A & 20A circuits serving outlet locations (except garage, and bathrooms) including receptacles, lights and smoke detectors, require combination type arc-fault circuit interrupters, 210.12(A).

Contact Jeremy Hamblin with any questions: Jeremy.hamblin@tucsonaz.gov
12/26/2025 Fire New Construction Standard REQUIRES RESUBMIT Resolve all building comments.
john.vincent@tucsonaz.gov
5203495581
12/04/2025 PDSD Application Completeness Express REVIEW COMPLETED