Permit Review Detail
Review Status: Requires Resubmit
Review Details: COMMERCIAL REVIEW - FULL v.1
Permit Number - TC-COM-1224-02440
Review Name: COMMERCIAL REVIEW - FULL v.1
Review Status: Requires Resubmit
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
01/24/2025 | Commercial Building | APPROVED | |||
01/23/2025 | Commercial Plumbing | APPROVED | |||
01/27/2025 | Site Zoning | APPROVED | |||
01/23/2025 | Water - PDSD | APPROVED | |||
01/27/2025 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
01/17/2025 | Commercial Electrical | REQUIRES RESUBMIT | Commercial Electrical Review: TC-COM-1224-02440 (602 N WILMOT RD TUCSON, AZ 85711) Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide updated Plans/calculations and a written response Letter to each of the notated items indicating action taken. Resubmitted plans that do not contain a written response Letter addressing each of the notated items indicating action taken, may be delayed until response letter is received. Code reference, 2018 International Building Code (IBC), 2017 National Electrical Code (NEC), 2012 Outdoor Lighting Code (OLC). General Comment: 1. Submitted plans are missing electrical and outdoor lighting pages. Provide complete electrical plans showing all proposed work. 2. This is a commercial project, requiring all documents to be prepared, sealed, signed, and dated by a registered design professional. Provide complete electrical plans, design, and calculations, sealed by an Arizona Registrant. Reference: Arizona Revised Statutes 32-125, Board of Technical Registration Rules R4-30-304, 2018 IBC section 107.1, 2017 NEC, City of Tucson Commercial Plan Submittal Requirements. Contact Jeremy Hamblin with any questions: Jeremy.hamblin@tucsonaz.gov |
||
01/23/2025 | Commercial Mechanical | REQUIRES RESUBMIT | 1. Provide exhaust for the art classroom. Reference: Section 403.3.1.1, IMC 2018. 2. Provide heating and cooling load calculations to justify the heating/cooling capacities of HVAC units AC-1 through AC-4. Reference: Sections C403.1.1 and C502.2.3, IECC 2018. |
||
01/17/2025 | Outdoor Lighting | REQUIRES RESUBMIT | Outdoor Lighting Review TC-COM-1224-02440 (602 N WILMOT RD TUCSON, AZ 85711) Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide updated Plans/calculations and a written response Letter to each of the notated items indicating action taken. Resubmitted plans that do not contain a written response Letter addressing each of the notated items indicating action taken, may be delayed until response letter is received. Code reference, 2018 International Building Code (IBC), 2017 National Electrical Code (NEC), 2012 Outdoor Lighting Code (OLC). General Comment: 1. Submitted plans are missing electrical and outdoor lighting pages. 2. This is a commercial project, requiring all documents to be prepared, sealed, signed, and dated by a registered design professional. Provide complete electrical plans, design, and calculations, sealed by an Arizona Registrant. Reference: Arizona Revised Statutes 32-125, Board of Technical Registration Rules R4-30-304, 2018 IBC section 107.1, 2017 NEC, City of Tucson Commercial Plan Submittal Requirements. Outdoor Lighting Review: >>> Address comments below or specify on the plans that no changes shall be made to the existing outdoor lighting. 3. Provide an outdoor lighting plan that meets the requirements of OLC 104.2. Show/locate the different light sources on your site plan. Number the light fixtures on your table and use the same number on your site plan 4. Show compliance with City of Tucson Outdoor Lighting Code with an approved lighting calculation in accordance with OLC 3.1.2. Include all exterior fixtures on the property in the calculations. Show unshielded fixtures with a maximum of 3,000 lumens, OLC 401.4. Show lamps with a maximum of 3500K color temperature, OLC 402.1. 5. Show compliance to total outdoor light output per 2012 City of Tucson/Pima County Outdoor Lighting Code section 401.2. Total outdoor light output shall not exceed the lumen limits listed in Table 401.1. 4. E1.1 – Lighting Code section 104.2.2. 6. Submit catalogue or specification sheets of the proposed light fixture illustrating the type of fixture they are whether full cut-off or unshielded. Contact Jeremy Hamblin with any questions: Jeremy.hamblin@tucsonaz.gov |
||
01/06/2025 | Fire New Construction | REVIEW COMPLETED | |||
01/02/2025 | PDSD Application Completeness Express | REVIEW COMPLETED | |||
01/27/2025 | Site Engineering | REVIEW COMPLETED |