Permit Review Detail
Review Status: Requires Resubmit
Review Details: COMMERCIAL REVIEW - FULL v.3
Permit Number - TC-COM-1224-02401
Review Name: COMMERCIAL REVIEW - FULL v.3
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 10/07/2025 | Commercial Plumbing | APPROVED | |||
| 10/23/2025 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 10/15/2025 | Fire New Construction | REQUIRES RESUBMIT | 1. I still cannot locate your updated comments regarding the fire alarm. Please update to show your intentions of installing a fire alarm in required buildings. Sheet T3.0 does not mention or indicate any information about fire alarms. Sheet T1.0, deferred submittals show "automatic fire sprinkler system" and "fire sprinkler systems." These are the same thing. Make a note that a fire alarm system will be installed and indicate which buildings. Fire alarm shall be in accordance with IFC 907 and NFPA 72. john.vincent@tucsonaz.gov 5203495581 |
||
| 10/14/2025 | Site Engineering | REQUIRES RESUBMIT | Permit: TC-COM-1224-02401 Location: 1767 E BENSON HY Review Date: 10/14/2025 Site Engineering Comments: 1. Site Engineering will be unable to review and approve permit TC-COM-1224-02401 until the associated development package TD-DEV-1224-00324 is reviewed and approved by all reviewers. If you have any questions or concerns, please contact Marco Contreras Marco.contreras@tucsonaz.gov |
||
| 10/23/2025 | Site Zoning | REQUIRES RESUBMIT | FROM: PDSD Zoning Review Section PROJECT: BLDG 1 = TC-COM-1224-02384, BLDG 2 = TC-COM-1224-02401, BLDG 3 = TC-COM-1224-02402, BLDG 4 =TC-COM-1224-02403, BLDG 5 = TC-COM-1224-02404, BLDG 6 = TC-COM-1224-02405, BLDG 7 = TC-COM-1224-02406, BLDG 8 = TC-COM-1224-02407, BLDG 9 = TC-COM-1224-02408, COVERED PARKING CANOPIES = TC-COM-1224-02409 - TD-DEV-1224-00324 1767 E BENSON HY. - C-2 Multifamily (3rd Review) TRANSMITTAL DATE: ‎October 23, 2025 COMMENTS: Resubmit revised drawings along with a detailed response letter, which states how all Zoning Review Section comments were addressed. This site is located in C-2 zone (UDC 4.7.24). Multifamily Use is a permitted use in the zone (UDC Table 4.8-4) 1. Comment: Zoning has reviewed the building plans for compliance with Development Package (DP) TD-DEV-1224-00324, and although it appears that the plans match until the DP is approved by all review agencies Zoning cannot approve the building plans. 2. Previous Comment is still applicable: The Parking Requirements shown on sheet T3.0 does not match what is shown on DP TD-DEV-1224-00324. Either ensure that the calculation matches or remove the calculation from the building plans. 3. Previous Comment 3: The Parking Units shown on sheet T1.0 shows a total of 388 parking units for the site but the DP shows 391 space provided. Clarify which is correct and ensure that the plans match or remove the calculation from the building plans. Follow up to Previous Comment 3: The Parking Units added together on sheet T1.0 equal a total of 390 parking units for the site but the DP shows 391 space provided. Clarify which is correct and ensure that the plans match or remove the calculation from the building plans. 4. Previous Comment is still applicable: The gross floor area listed in the Hud Apartment Tabulation sheet T1.0 for buildings 2-8, 26,655 GFA, does not match what is shown within the footprint of the buildings on the DP. Clarify which is correct and ensure the plans match. 5. Previous Comment is still applicable: The gross floor area listed in the Hud Apartment Tabulation sheet T1.0 for the recreation building, 2,803 GFA, does not match what is shown within the footprint of the building on the DP. Clarify which is correct and ensure the plans match. If you have any questions about this transmittal, please contact Ramiro.Olivarez@tucsonaz.gov. |
||
| 10/06/2025 | PDSD Application Completeness Express | REVIEW COMPLETED |