Permit Review Detail
Review Status: Requires Resubmit
Review Details: COMMERCIAL REVIEW - FULL v.2
Permit Number - TC-COM-1224-02396
Review Name: COMMERCIAL REVIEW - FULL v.2
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 03/14/2025 | Commercial Electrical | APPROVED | |||
| 03/24/2025 | Commercial Mechanical | APPROVED | |||
| 04/02/2025 | Site Engineering | APPROVED | |||
| 03/24/2025 | Water - PDSD | APPROVED | |||
| 03/14/2025 | Building Official Standard | NOT REQUIRED | A Building official appeal shall be submitted as a separate application at the direction of the commercial plans examiner. | ||
| 04/02/2025 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 03/27/2025 | Commercial Building | REQUIRES RESUBMIT | Adaptive reuse of historic chapel and courtyard space as performing arts venue and bar areas. Please submit your revised documents and provide a letter with a written response letter addressing each of the comments indicating how the Review comments were resolved. 2. Sheet G002: Please amend the plans to provide a summary of the code analysis as follows to ensure the C of O information matches the design and drawings. IBC 107.2.1: **NEW**Please clarify the following: A. The use and occupancy, in accordance with the provisions of Chapter 3. For example, A-2, B, etc. ** NEW**The occupancies listed on the plan include A-1, A-2, A-3, B & R-2. Are all these occupancies applicable and meant to be included on the C of O? If so, please identify the R-2 area on the plans. Additionally, the concert area in the old chapel area is shown as A-1 on the chapel code plan and A-3 in the Use and Occupancy Classification (IBC CH 3) table on sheet G002. Please amend plans to ensure all information is consistent throughout the plan set as this document is the record of work and will be used to populate the new C of O. IBC 107.2.1 C. The design occupant load. For example, 289 **NEW** Please recalculate and clarify total design occupant load as it does not appear to match the drawings. IBC 107.2.1 E. Total Square footage of Occupied Spaces. **NEW** The C of O requires the occupiable square footage included under this permit. Please clarify as it appears the number is 12,250, is this correct? Please let me know why 14,203 is listed in the narrative. 3. Sheet G-002: Please amend plans to identify the accessible entrances with at least 60% of the entrances are accessible. IBC 1105.1 Additionally, provide directional signage for any inaccessible entrances. IBC 111.2 **NEW**This comment has been expanded request an accessible route be shown on the plans to include continuation of Accessible access to the public way. For example, the Accessible exit at the staircase entrance is utilizing a ramp. What is the slope of the ramp and are guards required, are handrails installed on both sides with edge protection? IBC 1012.2, IBC 1012.8, IBC 1012.9 & IBC 1012.10 4. Sheet G-002: Please review plumbing fixture count as it appears 12 water closets would be required 5 for men and 7 for women IBC Table 2902.1 **NEW**Please see and comply with Commercial Plumbing review comments. 5. Sheet G-002: Please apply for an Appeal to the Building Official to allow the use of both water closets and lavatory fixtures for use by all persons regardless of sex as the 2018 IBC 2902.2 requires separate facilities for each sex. **NEW**Please apply for the Appeal to the Building Official within the workflow of this permit TDC online under Building Code Appeal 8. Please amend plans to show the current edition of the adopted codes and referenced standards. IBC 107.2.1 Treat as a typical note. For example, A. S101.1 Please amend to reference the current adopted code as Foundation Note 1. Indicates 2012 IBC **NEW**please replace 2012 with 2018 as our currently adopted version is the 2018 IBC 13. IEBC 305.7 requires that accessibility be provided to the altered spaces. Where the existing path of travel elements, which entails a primary entrance, a primary path of travel, sanitary facilities serving the area, a drinking fountain, and signs. If these items are in full compliance with the current code, provide a statement indicating this on the cover sheet of the drawings. **NEW** The previous statement of full compliance was stricken form this comment letter, as the statement implies the altered space requires no further improvements and is fully Accessible. **NEW** An accessible route shall directly connect the performance area to the assembly seating area where a circulation path directly connects a performance area to an assembly seating area. An accessible route shall be provided from performance areas to ancillary areas or facilities used by performers. IBC 1108.2.1 Performance areas, such as stages, band platforms, choir lofts and similar spaces, must be accessible. If there is a direct route from the seating to the performance area, there must also be an accessible route. For example, if steps are provided from the assembly seating area to the stage within the theater, then an accessible route (e.g., a ramp or platform lift) to the stage must also be provided within the theater. An accessible route must also be provided to any ancillary areas, such as green rooms or practice/warm-up rooms. The intent is that a person with mobility impairments could participate in the event. This could include high-school graduation with students coming from the audience onto the stage to receive their diplomas; participating with the community band; playing in the orchestra for a performance; acting in a production; or giving a speech. Technical production areas for the stage, such as catwalks, are exempted under Section 1103.2.7. Accessibility upgrades shall be required in accordance with IEBC.305.7. 1. If the cost of providing or upgrading the items above to be accessible is disproportionate to the cost of construction (exceeds 20% of the cost of construction not including accessibility upgrades), please provide information to verify construction costs. (A) Alterations made to provide an accessible path of travel to the altered area will be deemed disproportionate to the overall alteration when the cost exceeds 20% of the cost of the alteration to the primary function area. (B) Costs that may be counted as expenditures required to provide an accessible path of travel may include: For example, costs associated with making restrooms accessible, such as installing grab bars, enlarging toilet stalls, insulating pipes, or installing accessible faucet controls. **NEW** B The stated valuation of the project is $876,450 leaving $175,290 available for Accessibility upgrades Please contact me if you have any questions about these comments. Mark Masek Plans Examiner – Building Safety Planning and Development Services | City of Tucson main 520.837.4994 email mark.masek@tucsonaz.gov |
||
| 03/24/2025 | Commercial Plumbing | REQUIRES RESUBMIT | 1. The new calculation adds 2 water closets located in basement and are available for use. The total number of required water closets on the first floor is then 7 (2 for men and 5 for women). Only 6 water closets are shown. What am I missing? [Initial comment: The substitution of urinals for a maximum of 67% of the water closets applies only to the water closets designated for men. Based on your calculations, in separate facilities, there would be 7 water closets for women and 5 water closets for men. With 2 water closets and 3 urinals for the men, you still require 7 water closets for the women (one of which can be used for the required family restroom, Section 1109.2.1, IBC 2018). Reference: Section 424.2, IPC 2018.] 2. The Appeal to the Building Official for included with this submittal is not legible. Correct the section detailing what is proposed in literal compliance with the code ( Section 2902.1, IBC 2018 and Section 405..3.2, IPC 2018). |
||
| 03/26/2025 | Site Zoning | REQUIRES RESUBMIT | FROM: PDSD Zoning Review Section PROJECT: TC-COM-1224-02396 800 N Country Club Rd, Bldg 1, Tucson, AZ 85716 Commercial Alteration/Addition (2nd Review) TRANSMITTAL DATE: March 26, 2025 COMMENTS: Resubmit revised drawings along with a detailed response letter, which states how all Zoning Review Section comments were addressed. This site is located in PAD-37. 1. The submitted plans appear to match the approved development package, TD-DEV-0624-00182; however, approval by Historic Review will be necessary before Site Zoning can provide final approval of this permit. REQUIRED: Resubmitted plans following final Historic Review approval. If you have any questions about this transmittal, please contact Site Zoning Reviewer Fernando Garcia at fernando.garcia2@tucsonaz.gov. |
||
| 04/01/2025 | Historic Standard | REVIEW COMPLETED | This was reviewed by PRS and recommended approval. No further historic review for this aspect of the project. As a city HL, any other exterior modifications will require PRS review. Contact Michael.Taku@tucsonaz.gov |
||
| 03/10/2025 | PDSD Application Completeness Express | REVIEW COMPLETED |