Permit Review Detail
Review Status: Requires Resubmit
Review Details: COMMERCIAL REVIEW - FULL v.2
Permit Number - TC-COM-1224-02368
Review Name: COMMERCIAL REVIEW - FULL v.2
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 02/10/2025 | Commercial Building | APPROVED | Structural(S) Reviewer Madeline Nelson mnelson@safebuilt.com Approved Reason: Date Completed : 2/8/2025 6:55:59 PM Building(B) Reviewer Keith Miller kmiller@safebuilt.com Approved Reason: Date Completed : 2/6/2025 9:59:20 AM The plans are approved. Subject to the field inspector’s approval. The completed Special Inspection Intermediate Certificate is to be submitted. |
||
| 02/10/2025 | Commercial Electrical | APPROVED | Electrical(E) Reviewer Ron Ross rross@safebuilt.com Approved with Comments Reason: Date Completed : 2/5/2025 3:45:29 PM |
||
| 02/10/2025 | Outdoor Lighting | APPROVED | Electrical(E) Reviewer Ron Ross rross@safebuilt.com Approved with Comments Reason: Date Completed : 2/5/2025 3:45:29 PM |
||
| 02/20/2025 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 02/10/2025 | Commercial Plumbing | REQUIRES RESUBMIT | Plumbing(P) Reviewer Perry Hendershott phendershott@safebuilt.com Denied Reason: Date Completed : 2/6/2025 11:35:44 PM Second Plumbing Review: Comment 5 Remains Resolved-1). Plan Page A1.7: Missing Roof Drainage Method. Add roof drainage method with calculations. -2018 IPC 1101.2, 1106.1, 1106.2, 1106.3, 1106.6, 1108 Resolved-2). Plan Page A1.7: Missing location of adjacent secondary scuppers. Add adjacent secondary scuppers. - 2018 IPC 1106.5. 1108 Resolved-3). Plan page P1.1: Roof drain calc table missing conductor information. Add conductor information to roof drainage calc table. -2018 IPC 1106.3 Resolved-4). Plan Page P1.1: Missing location of adjacent secondary scuppers. Add adjacent secondary scuppers. - 2018 IPC 1106.5. 1108 UNRESOLVED-5). Plan page P1.1.1 detail 2: add note for indirect waste piping that exceeds distances listed in -2018 IPC 802.3 will need to be trapped. Resolved-6). Plan page P1.3: Water system detail is missing backflow protection for the H201 Oven water connection. Add backflow protection for the H201 Oven water connection. -2018 IPC 608.3 Resolved-7). Plan pages P1.1.1 & P1.2: Grease laden waste needs to discharge to the grease system. The H201 Oven floor sink needs to connect to the grease system, -2018 IPC 1003.1 |
||
| 02/20/2025 | Site Engineering | REQUIRES RESUBMIT | See zoning comment Ryan Insalaco – ryan.insalaco@tucsonaz.gov |
||
| 02/20/2025 | Site Zoning | REQUIRES RESUBMIT | FROM: Ramiro Olivarez PDSD Zoning Review Section PROJECT: TC-COM-1224-02368 – Commercial Building (ref. TD-DEV-0723-00337) 2 N FREEWAY – I-1| C-3 This site is zoned I-1 and C-3. Retail Use Group – General Merchandise Sales (Fuel Station) is a permitted use in these zones. (1st Review) TRANSMITTAL DATE: February 20, 2025 COMMENTS: Resubmit revised drawings along with a detailed response letter, which states how all Zoning Review Section comments were addressed. 1. Comment: Although the plan appears to match, final Site Zoning approval of this plan cannot occur until development package, TD-DEV-0723-00337, is approved. Once approved, please resubmit the building permit. Ensure the building permit documents match the approved development package if any changes to the DP are made. RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Approval of TD-DEV-0723-00337 and resubmittal of revised plans. If you have any questions about this transmittal, please contact Ramiro Olivarez at Ramiro.Olivarez@tucsonaz.gov |
||
| 02/05/2025 | PDSD Application Completeness Express | REVIEW COMPLETED |