Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Number: TC-COM-1224-02307
Parcel: 128010510

Review Status: Requires Resubmit

Review Details: COMMERCIAL REVIEW - FULL v.2

Permit Number - TC-COM-1224-02307
Review Name: COMMERCIAL REVIEW - FULL v.2
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
01/21/2025 Commercial Mechanical APPROVED Mechanical(M) Reviewer
Jorge Valido
jvalido@safebuilt.com
Approved
Reason:
Date Completed : 1/21/2025 10:23:38 AM
01/21/2025 Bldg Permits - Post Review Express PENDING ASSIGNMENT
01/21/2025 Commercial Building REQUIRES RESUBMIT Structural(S) Reviewer
Madeline Nelson
mnelson@safebuilt.com
Approved
Reason:
Date Completed : 1/18/2025 10:36:40 PM



Building(B) Reviewer
Kimiyoshi Shimabukuro
kshimabukuro@safebuilt.com
Denied
Reason:
Date Completed : 1/18/2025 6:51:05 AM
1. Provide Special Inspections Intermediate Certificate
◦ A Special Inspections Intermediate Certificate must be submitted and reviewed prior to issuance of this permit. Provide signed/dated certificate:
◦ You may obtain the form at the following link:
◦ https://www.tucsonaz.gov/files/sharedassets/public/v/1/city-services/planning-developmentservices/documents/special_inspection_certificate.pdf
◦ he Condition is added to the permit and then satisfied upon approval of the form. (Closed)

2. Sheet A1.0 – Architectural floor plan does not show vestibules per 2018 IECC section C402.5.7. Building entrances shall be protected with an enclosed vestibule, with all doors opening into and out of the vestibule equipped with selfclosing devices. Site and explain exceptions when applicable. (Closed)

3. X1.0 – Although labeled as abandoned space 121, there is potential access through the hallway by occupants. Permanently closed door can mislead any occupants during emergency. Also show the common path of travel
distance per 2018 IBC table 1006.2.1.

4. X1.0 – Show the hallway width into men’s fitting room 106 and ADA turn clearance at the change of direction. Appears to provide 60” diameter turn radius once in the room but unclear how wheelchair can turn at the prior right angle hallway. Similar issue at office hall 119. Show hallway width: how ADA access into manager’s office 104 which indicates 60” diameter maneuvering clearance. (Closed)
01/16/2025 PDSD Application Completeness Express REVIEW COMPLETED