Permit Number: TC-COM-1223-02913
Parcel: 11206219B

Review Status: Requires Resubmit

Review Details: COMMERCIAL REVIEW - FULL v.1

Permit Number - TC-COM-1223-02913
Review Name: COMMERCIAL REVIEW - FULL v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
01/24/2024 Bldg Permits - Post Review Express PENDING ASSIGNMENT
01/24/2024 Site Engineering REQUIRES RESUBMIT See zoning comment
12/29/2023 Site Zoning REQUIRES RESUBMIT ZONING REVIEW TRANSMITTAL

FROM: PDSD Zoning Review

PROJECT:
TC-COM-1223-02913
2574 N CAMPBELL AV. – C-1
Food & Beverage Sales (1st Review)

TRANSMITTAL: December 29, 2023

Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review Section comments were addressed.

This site is located in C-1 zone (UDC 4.7.20), Food Service is a permitted use in the zone subject to Use Specific Standard 4.9.13.O.

1. Zoning has reviewed the building plans for compliance with Development Package (DP) TD-DEV-0823-00382 and the following comments need to be addressed. Until the following comments are addressed and the DP is approved by all review agencies Zoning cannot approve the building plans.

2. The building plan does not match the submitted DP.
Sheet AS1.0
a. Extents of concreter work along the east and west end of the building
b. Pedestrian crosswalk located near the southwest corner of the building do not match. Also the sign mounting height shown on detail 31 sheet AS1.2 does not match what is shown on DP detail A, sheet 6.
Sheet AS1.2
a. Sign mounting height shown on detail 31 does not match what is shown on DP detail A, sheet 6.
Sheet CS & A1.0
a. Based on the building area 1, 448 and the floor plan dimensions the building area does not match what is shown on the DP, 1,029 SF.

If you have any questions about this transmittal, please contact Zone1.desk@tucsonaz.gov.
01/23/2024 Water - PDSD REQUIRES RESUBMIT Provide the civil plans showing the installation of the water service to the building as part of the building plan set. Reference: Sections 107.2.1 and 107.2.6, IBC 2018.
12/29/2023 External Reviewers - SAFEBuilt REVIEW COMPLETED Structural(S) Reviewer
Kimiyoshi Shimabukuro
kshimabukuro@safebuilt.com
Approved
Reason:
Date Completed : 12/28/2023 8:27:50 PM




Building(B) Reviewer
Kimiyoshi Shimabukuro
kshimabukuro@safebuilt.com
Approved
Reason:
Date Completed : 12/28/2023 8:27:41 PM



Mechanical(M) Reviewer
Kimiyoshi Shimabukuro
kshimabukuro@safebuilt.com
Approved
Reason:
Date Completed : 12/28/2023 8:28:06 PM



Electrical(E) Reviewer
Kimiyoshi Shimabukuro
kshimabukuro@safebuilt.com
Approved
Reason:
Date Completed : 12/28/2023 8:28:13 PM



Plumbing(P) Reviewer
Kimiyoshi Shimabukuro
kshimabukuro@safebuilt.com
Approved
Reason:
Date Completed : 12/28/2023 8:27:58 PM
01/23/2024 Fire New Construction REVIEW COMPLETED This occupancy type does not require a fire alarm. Sheet CS states fire alarm will be a deferred submittal. You can install a fire alarm if you'd like. Contact me and I will approve the plans as is or you can remove the fire alarm notes and submit a revision.

01/23/24
Stated they will be installing a FA.
Doug Tennor 602-792-1781
john.vincent@tucsonaz.gov
5203495581
12/26/2023 PDSD Application Completeness Express REVIEW COMPLETED