Permit Review Detail
Review Status: Requires Resubmit
Review Details: COMMERCIAL REVIEW - FULL v.1
Permit Number - TC-COM-1223-02909
Review Name: COMMERCIAL REVIEW - FULL v.1
Review Status: Requires Resubmit
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
05/28/2024 | Bldg Permits - Post Review | PENDING ASSIGNMENT | |||
05/28/2024 | External Reviewers - Stantec | REQUIRES RESUBMIT | May 24, 2024 1st Review Seaver Franks Attn: Rick Huch/Nurlan Herburger 2552 N. Alvernon Way Tucson, Arizona 85712 Re: SAAF-NPS PHARMACY TENANT IMPROVEMENT - REVISIONS City of Tucson Permit Number: TC-COM-1223-02909 Stantec Project Number: 185215066 Stantec File Number: TUC-24-051 Plan review for the above referenced project has been completed. This letter reflects comments to be addressed. To facilitate a shorter back-check time, we request that you please, only provide plans and calculation pages that have been revised, clouding any changes, along with a written response to each of the noted items indicating the action taken. The scope of this review covers the architectural, structural, plumbing, mechanical, and electrical designs as they relate to the codes adopted by the jurisdiction. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions, and concerns before permit approval. Occupancy Group Construction Type Area (Square feet) Occupant Load Automatic Fire Sprinklers Fire Alarms B V-B 16,400 203 Yes No M Separate Permits: Automatic fire sprinklers. Deferred Submittals: None. Special Inspections: None. ARCHITECTURAL COMMENTS There are no comments. STRUCTURAL COMMENTS Sheet A7.0 1. Please provide the engineer’s structural calculations for the Tilt Panel Openings design. [Ref. IBC 2018 Sec.1604.4] MECHANICAL COMMENTS There are no comments. PLUMBING COMMENTS There are no comments. ELECTRICAL COMMENTS There are no comments. Should you have any questions regarding the plan review comments, please contact the plan reviewer listed for the appropriate discipline. Plans reviewed by: Trevor Bies, Senior Plan Reviewer 602-338-9922 trevor.bies@stantec.com |
||
05/07/2024 | Fire New Construction | REVIEW COMPLETED | |||
05/03/2024 | PDSD Application Completeness | REVIEW COMPLETED |