Permit Review Detail
Review Status: Requires Resubmit
Review Details: COMMERCIAL REVIEW - FULL v.2
Permit Number - TC-COM-1223-02906
Review Name: COMMERCIAL REVIEW - FULL v.2
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 03/12/2024 | Site Engineering | NOT REQUIRED | |||
| 03/18/2024 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 03/18/2024 | Commercial Structural | REQUIRES RESUBMIT | ACTIVITY NO. TC-COM-1223-02906 ADDRESS/PARCEL: (4743 E BELLEVUE ST TUCSON, AZ 85712) Submit your revised drawings along with a detailed response letter, which states how all Building Review Section comments were addressed. The submitted documents were incomplete and a thorough plan review could not be performed. Please be aware, new comments may arise with the next review. COMMENTS: 1. Include a statement as part of your code analysis as to how the facility handles any persons receiving custodial care who require limited verbal or physical assistance responding to an emergency situation to complete building evacuation and self preservation. As stated for those care facilities allowed within the R-3 occupancy, the persons receiving care in a building designed according to the IRC are not limited to those who are capable of self-preservation. Similar to Sections 308.2.4 and 308.3.2 condition 1 or condition 2, this section specifies that any such IRC-regulated facility be provided with a sprinkler system per 310.4.1 Care facilities within a dwelling (this will determine the type of fire sprinkler system the fire department will require). 2. On the Site Plan show/indicate the Accessible route from drop off location to the accessible entry door complying to IBC 106 & ANSI A117. 3. In an Emergency, show/locate the gathering area/dispersal area where it is safe from danger minimum 50 ft away from structure per IBC 310.5 and 1028.5. 4. Indicate the clear opening of the doors complying to ANSI A117. 5. Indicate the clear width of hallways. 6. Show/locate the side & back grab bars at the Water Closet as well as at the Shower, make sure to indicate the installation of Structural Backer Board for these grab bars per IBC Chapter 11. 7. Provide Emergency Escape & Rescue Openings per R310 at every bedroom/sleeping space. On the drawing adjacent to the opening(s), indicate the clear opening for both horizontally and vertically and provide the dimension from the finish floor to the bottom of the opening. Indicate if there are obstacles on either side of the opening. 8. Tucson Fire Department will conduct fire inspection as part of this permit, the inspection approval document will be required to be submitted as a deferred submittal before issuing the Certificate of Occupancy. 9. Illumination with emergency backup power is required in all components of the means of egress system [IBC 1008]. Please locate those equipments including the lighted exit sign on your plan (to be inspected by Tucson Fire Department). Electrical work (conductors/wiring/breaker ONLY) related to the installation of Emergency Lights, Lighted Signs, Fire/Audible/Smoke Alarms/Fire Extinguisher will be inspected by City of Tucson inspectors, show on your plans so that our inspectors will know what wiring/breaker to inspect and shall also be reviewed as part of this permit. Any new renovation work must be included as part of this building permit. 10. An Operator's License must be applied for with the State, the absence of this license shall void this building permit. 11. Submit a draft copy of the State License application confirming the exact use title for the certificate of occupancy document. 12. Please re-submit. |
||
| 03/14/2024 | Site Zoning | REQUIRES RESUBMIT | ZONING REVIEW TRANSMITTAL FROM: Wyatt Berger Lead Planner PROJECT: TC-COM-1223-02906 4743 East Bellevue Street – R-1 Residential Care Services (1st Review) TRANSMITTAL DATE: March 14, 2024 Please resubmit revised drawings with a detailed response letter stating how all Zoning Review Section comments were addressed. 1. Identify the Residential Care Services land use type proposed. Both Adult Care Service and Physical and Behavioral Health Service uses are permitted in the R-1 zone, subject to use-specific standards 4.9.7.J.2.a, .3.a, and .4. 2. Per Tucson Unified Development Code (UDC) Table 7.4.4-1, three motor vehicle parking spaces are required for Residential Care Services uses with one to five residents. Show the three required motor vehicle parking spaces on the site plan. If you have any questions about this transmittal, contact me at Wyatt.Berger@tucsonaz.gov or at 520-837-4951. |
||
| 03/12/2024 | Fire New Construction | REVIEW COMPLETED | |||
| 02/15/2024 | PDSD Application Completeness Express | REVIEW COMPLETED |