Permit Review Detail
Review Status: Requires Resubmit
Review Details: COMMERCIAL REVIEW - FULL v.2
Permit Number - TC-COM-1223-02789
Review Name: COMMERCIAL REVIEW - FULL v.2
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 03/01/2024 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 02/08/2024 | External Reviewers - SAFEBuilt | REQUIRES RESUBMIT | Structural(S) Reviewer Madeline Nelson mnelson@safebuilt.com Approved Reason: Date Completed : 12/20/2023 10:40:13 AM Building(B) Reviewer Andrew Bevis abevis@safebuilt.com Approved Reason: Date Completed : 12/18/2023 5:20:32 PM Mechanical(M) Reviewer Jorge Valido jvalido@safebuilt.com Denied Reason: Date Completed : 2/5/2024 10:49:11 AM 1. General - Provide Manufacturer Hood Plans - 2018 International Mechanical Code section 507.1 - 2018 International Energy Conservation Code Section C103.2Information on construction documents (4) (UNRESOLVED) i. Provide Manufacturer Hood LISTED plans.- 2018 International Mechanical Code section 507.1 - 2018 International Energy Conservation Code Section C103.2 Information on construction documents (4) 2. General - Provide Manufacturer Fire Suppression Plans - 2018 International Mechanical Code Section 509.1 - 2018 International Energy Conservation Code Section C103.2Information on construction documents (4) (UNRESOLVED) i. Provide Manufacturer Fire Suppression LISTED plans.- 2018 International Mechanical Code section 507.1 - 2018 International Energy Conservation Code Section C103.2Information on construction documents (4) 3. General - Provide Roof Plan. Show on roof plan all distances from edge of building to HVAC equipment and Hood supply and exhaust equipment. If applicable provide Guards for all equipment - 2018 International Mechanical Code Section [BE] 304.11. (RESOLVED) Electrical(E) Reviewer Ron Ross rross@safebuilt.com Approved with Comments Reason: Date Completed : 12/14/2023 12:57:29 PM Electrical Review of Meteor Café By: Ron Ross PE E2.0 POWER PLAN: Some numbers do not correlate to the panel schedule descriptions. Would suggest to relocate electrical panels from utility room between Janitor’s sink and Water Heater. Suggestion only, as design is code compliant, but may receive negative feedback from a local field inspector. Plumbing(P) Reviewer Perry Hendershott phendershott@safebuilt.com Denied Reason: Date Completed : 2/7/2024 11:04:00 PM Second Plumbing Review: Unresolved-1). Hydro mechanical grease interceptor on plan page G250 on plan page P1 can only receive discharge from 4 fixtures & Zero dishwashers per Tucson Plumbing Code Amendments. ** Per the Schier Website The GB-250 is not a gravity grease interceptor see models at https://schierproducts.com/shop ** Resolved-2). Water connection to Number 53 beer dispenser on plan page P5 needs backflow protection, -IPC 608.17 Resolved-3). Add Gas sizing table used & system legnth to plan page P3 -IFGC 402.3 Resolved-4). Grease interceptor on plan page P1 needs to be vented. -IPC 1003.9 |
||
| 02/29/2024 | Site Engineering | REQUIRES RESUBMIT | 1. Site Engineering cannot approve TC-COM-1223-02789 until the associated development package, TD-DEV-1022-00004, is approved. Lianne Evans lianne.evans@tucsonaz.gov |
||
| 03/01/2024 | Site Zoning | REQUIRES RESUBMIT | ZONING REVIEW TRANSMITTAL FROM: Wyatt Berger Lead Planner PROJECT: TC-COM-1223-02789 901 West Congress Street – C-1 The Meteor Cafe (2nd Review) TRANSMITTAL DATE: March 1, 2024 Please resubmit revised drawings with a detailed response letter stating how all Zoning Review Section comments were addressed. 1. Zoning has reviewed the building plans for compliance with the associated development package TD-DEV-1022-00004. Although it appears the building plan footprint, building height, and square footage are consistent with the submitted development package, Zoning cannot approve TC-COM-1223-02789 until the associated development package is approved. If you have any questions about this transmittal, contact me at Wyatt.Berger@tucsonaz.gov or at 520-837-4951. |
||
| 02/29/2024 | Fire New Construction | REVIEW COMPLETED | |||
| 02/02/2024 | PDSD Application Completeness Express | REVIEW COMPLETED |