Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit Review Detail
Review Status: Approved
Review Details: COMMERCIAL REVIEW - FULL v.3
Permit Number - TC-COM-1223-02789
Review Name: COMMERCIAL REVIEW - FULL v.3
Review Status: Approved
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 04/16/2024 | Site Engineering | APPROVED | |||
| 04/15/2024 | Site Zoning | APPROVED | |||
| 04/16/2024 | Bldg Permits - Post Review Express | REVIEW COMPLETED | |||
| 03/22/2024 | External Reviewers - SAFEBuilt | REVIEW COMPLETED | Structural(S) Reviewer Madeline Nelson mnelson@safebuilt.com Approved Reason: Date Completed : 12/20/2023 10:40:13 AM Building(B) Reviewer) Andrew Bevis abevis@safebuilt.com Approved Reason: Date Completed : 12/18/2023 5:20:32 PM Mechanical(M) Reviewer Jorge Valido jvalido@safebuilt.com Approved Reason: Date Completed : 3/20/2024 11:50:38 AM 1. General - Provide Manufacturer Hood Plans - 2018 International Mechanical Code section 507.1 - 2018 International Energy Conservation Code Section C103.2 Information on construction documents (4) i. Provide Manufacturer Hood LISTED plans.- 2018 International Mechanical Code section 507.1 - 2018 International Energy Conservation Code Section C103.2Information on construction documents (4) (RESOLVED) 2. General - Provide Manufacturer Fire Suppression Plans - 2018 International Mechanical Code Section 509.1 - 2018 International Energy Conservation Code Section C103.2Information on construction documents (4) Provide Manufacturer Fire Suppression LISTED plans.- 2018 i. International Mechanical Code section 507.1 - 2018 International Energy Conservation Code Section C103.2Information on construction documents (4) (RESOLVED) Electrical(E) Reviewer Ron Ross rross@safebuilt.com Approved with Comments Reason: Date Completed : 12/14/2023 12:57:29 PM Electrical Review of Meteor Café By: Ron Ross PE E2.0 POWER PLAN: Some numbers do not correlate to the panel schedule descriptions. Would suggest to relocate electrical panels from utility room between Janitor’s sink and Water Heater. Suggestion only, as design is code compliant, but may receive negative feedback from a local field inspector. Plumbing(P) Reviewer Perry Hendershott phendershott@safebuilt.com Approved with Comments Reason: Date Completed : 3/20/2024 9:19:31 PM Third Plumbing Review: OK Subject to Field inspections Resolved-1). Hydro mechanical grease interceptor on plan page G250 on plan page P1 can only receive discharge from 4 fixtures & Zero dishwashers per Tucson Plumbing Code Amendments. ** Per the Schier Website The GB-250 is not a gravity grease interceptor see models at https://schierproducts.com/shop ****See Attached Email From Utility Authority allowing this Grease Interceptor** Resolved-2). Water connection to Number 53 beer dispenser on plan page P5 needs backflow protection, -IPC 608.17 Resolved-3). Add Gas sizing table used & system legnth to plan page P3 -IFGC 402.3 Resolved-4). Grease interceptor on plan page P1 needs to be vented. -IPC 1003.9 |
||
| 03/16/2024 | PDSD Application Completeness Express | REVIEW COMPLETED |