Permit Review Detail
Review Status: Requires Resubmit
Review Details: COMMERCIAL REVIEW - FULL v.1
Permit Number - TC-COM-1222-00388
Review Name: COMMERCIAL REVIEW - FULL v.1
Review Status: Requires Resubmit
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
01/12/2023 | Site Zoning | APPROVED | |||
01/26/2023 | Site Engineering | NOT REQUIRED | |||
01/26/2023 | Bldg Permits - Post Review | PENDING ASSIGNMENT | |||
01/23/2023 | External Reviewers - SAFEBuilt | REQUIRES RESUBMIT | Activity Number: TC-COM-1222-00388 GENERAL: Provide written responses to all review comments. Provide a complete plan set. Provide additional documents as requested by review staff. STRUCTURAL REVIEW COMMENTS: DENIED UNABLE TO COMPLETE THE REVIEW. THE PLANS SEALED BY A CIVIL ENGINEER SPECIFY " THE ENGINEERING REFERENCED ON THIE PLAN IS FOR POOL SHELL CONSTRUCTION ONLY" - NEED A FULL SET OF SEALED CONSTRUCTION DRAWINGS FOR ALL DETAILS SHOWN AND MISSING FOR ALL STRUCTURES. NEED THE STRUCTURAL PLANS FOR THE BUILDING. THE POOL AND BUILDING PLANS NEED THE OCCUPANCY, OCCUPANT LOAD PER ISPSC SECTION 608.1 SHOWN. INCORRECT IBC SECTIONS AND TABLES REFERENCED. PLANS ARE TO INCLUDE LOADS USED IN DESIGN OF THE STRUCTURES. BUILDING REVIEW COMMENTS: DENIED UNABLE TO COMPLETE THE REVIEW. THE PLANS SEALED BY A CIVIL ENGINEER SPECIFY " THE ENGINEERING REFERENCED ON THIE PLAN IS FOR POOL SHELL CONSTRUCTION ONLY" - NEED A FULL SET OF SEALED CONSTRUCTION DRAWINGS FOR ALL DETAILS SHOWN AND MISSING FOR ALL STRUCTURES. NEED THE PLANS FOR THE BUILDING INCLUDING STRUCTURAL, ACCESSIBILTY, AND ALL MECHANICAL AND PLUMBING PLANS. SHOW ACCESSIBLE ROUTES FROM THE PARKING SPACES. THE POOL AND BUILDING PLANS NEED THE OCCUPANCY, OCCUPANT LOAD PER ISPSC SECTION 608.1 SHOWN. INCORRECT IBC SECTIONS AND TABLES REFERENCED. DRAWINGS ARE TO SHOW THE DETAILS REQUIRED BY THE IECC. INCLUDE THE ENVELOPE AND MECHANICAL COMCHECK PARTS SHOWING COMPLIANCE. PLANS NEED TO SHOW THE BONDING OF ALL EQUIPMENT BEING INSTALLED, FULL POOL SHELL REINFORCEMENT AND BONDING, POOL DECK BONDING WITHIN 5FT OF THE POOL WALL, ETC. PLANS ARE TO INCLUDE LOADS USED IN DESIGN OF THE STRUCTURES. SUCTION ENTRAPMENT AVOIDANCE REQUIREMENTS ARE TO BE MET (APSP 7). |
||
01/10/2023 | Fire New Construction | REVIEW COMPLETED | |||
01/03/2023 | PDSD Application Completeness | REVIEW COMPLETED |