| 11/04/2026 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 11/04/2026 | Commercial Plumbing Express | REQUIRES RESUBMIT | Provide the water demand that this water service will supply and calculations showing how the water service piping has been sized. The existing water service pipe 2-inch IPS galvanized steel with an internal diameter of 2.067” (assuming schedule 40). The proposed 2-inch PEX has an internal diameter of 1.629”. Reference: Sections 603.1, IPC 2024. If you have any questions about this review comment, I can be reached at Robert.Sherry@tucsonaz.gov |
||
| 11/04/2026 | PDSD Application Completeness Express | REVIEW COMPLETED |