Permit Number: TC-COM-1126-01805
Parcel: 126191970

Address:
4425 E 22ND ST

Review Status: Requires Resubmit

Review Details: COMMERCIAL PDSD SIMPLE REVIEW v.1

Permit Number - TC-COM-1126-01805
Review Name: COMMERCIAL PDSD SIMPLE REVIEW v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
11/04/2026 Bldg Permits - Post Review Express PENDING ASSIGNMENT
11/04/2026 Commercial Plumbing Express REQUIRES RESUBMIT Provide the water demand that this water service will supply and calculations showing how the water service piping has been sized. The existing water service pipe 2-inch IPS galvanized steel with an internal diameter of 2.067” (assuming schedule 40). The proposed 2-inch PEX has an internal diameter of 1.629”. Reference: Sections 603.1, IPC 2024.
If you have any questions about this review comment, I can be reached at Robert.Sherry@tucsonaz.gov
11/04/2026 PDSD Application Completeness Express REVIEW COMPLETED