Permit Number: TC-COM-1124-02231
Parcel: 13213120G

Address:
3520 S KINO PW

Review Status: Requires Resubmit

Review Details: COMMERCIAL REVIEW - FULL v.2

Permit Number - TC-COM-1124-02231
Review Name: COMMERCIAL REVIEW - FULL v.2
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
02/06/2025 Commercial Electrical APPROVED Electrical(E) Reviewer
Ron Ross
rross@safebuilt.com
Approved with Comments
Reason:
Date Completed : 1/31/2025 1:49:49 PM
1. E-102 SITE PHOTOMETRIC PLAN: Should provide a Tucson city exterior illumination calculation as per Tucson
permit requirements. Addressed, provided calculation as separate report
02/06/2025 Commercial Mechanical APPROVED Mechanical(M) Reviewer
Jorge Valido
jvalido@safebuilt.com
Approved
Reason:
Date Completed : 2/3/2025 9:17:41 AM
02/06/2025 Commercial Plumbing APPROVED Plumbing(P) Reviewer
Perry Hendershott
phendershott@safebuilt.com
Approved
Reason:
Date Completed : 2/6/2025 12:37:36 AM
02/18/2025 Bldg Permits - Post Review Express PENDING ASSIGNMENT
02/06/2025 Commercial Structural REQUIRES RESUBMIT Structural(S) Reviewer
Madeline Nelson
mnelson@safebuilt.com
Approved
Reason:
Date Completed : 2/5/2025 5:41:17 PM


Building(B) Reviewer
Kimiyoshi Shimabukuro
kshimabukuro@safebuilt.com
Denied
Reason:
Date Completed : 2/1/2025 3:57:51 PM
1. Provide construction documents that are stamped/seal/dated by registered design professional. Stamp missing in
sheets like MH/U23 sheets that indicates that drawings must be checked and signed, K sheets, Q44242 sheets, and F
sheets. (2018 IBC section 107.1). Sheet index lists over 150 pages of documents but only 42 pages submitted.
Please provide drawing set that matches the sheet index scope. Geotechnical engineering report is not
signed/sealed either (Draft was provided).

2. Provide Special Inspections Intermediate Certificate
◦ A Special Inspections Intermediate Certificate must be submitted and reviewed prior to issuance of this permit.
Provide signed/dated certificate:
◦ You may obtain the form at the following link: Special inspection certification still missing registrational seal
and signature, category and special inspector.
◦ https://www.tucsonaz.gov/files/sharedassets/public/v/1/city-services/planning-developmentservices/documents/special_inspection_certificate.pdf
◦ The Condition is added to the permit and then satisfied upon approval of the form.
3. CFA05676 page 61 of 72 marked as “top reinforcing mat required” and “hand check required for anchor pullout.”
(Closed)
4. CFA05676 from page 70 of 72 indicates cantilevered retaining wall but this retaining wall is missing from Civil sheet
site plan (4 of 27) to clarify scope of work. (2018 IBC section 107.2.1) (Closed)
5. G-000 – shows “items of importance” one listed – Please be specific what this is in the document. (Closed)
6. G-000 or G-003 – City of Tucson applicable building codes are not listed. Select and provide all applicable building
codes including their edition years. (Closed)
City of Tucson IBC Local Amendments
• Amendments to the 2018 International Building Code
• Amendments to the 2018 International Existing Building Code
• Amendments to the 2018 International Energy Conservation Code
• Amendments to the 2018 International Fuel Gas Code
• Amendments to the 2018 International Mechanical Code
• Amendments to the 2018 International Plumbing Code
• Amendments to the 2018 International Residential Code
• Amendments to the 2018 International Swimming Pool & Spa Code
• Amendments to the 2017 National Electrical Code
• Amendments to the 2018 International Fire Code
• City of Tucson/Pima County Outdoor Lighting Code
• Arizona Administrative Code Title 18 Chapter 5 for public and semi-public swimming pools
• ICC A117.1 - 2009 Accessible and Usable Buildings and Facilities (by reference)
Adopting Local Amendments to the Building Code is authorized by Ordinance #11590.
1. G-003 – Code summary doesn’t state the scope of the fire alarm system. Response narrative missing from 7 to 9.
Provide complete drawings to issue for construction.
2. A-103 – Refuse enclosure roof plan missing.
3. A-104 – Order point canopy roof plan missing. (Closed)
◦ 10. S-001 – Overlapping texts makes the document illegible.
02/18/2025 Site Zoning REQUIRES RESUBMIT PDSD TRANSMITTAL FROM: Fernando Garcia Planning & Development Services Department – Zoning Review Section PROJECT: TC-COM-1124-02231 – Commercial Building (ref. TD-DEV-0224-00058) 3530 S Kino Pw, Tucson, AZ 85713 Plan Review (5th Review) TRANSMITTAL DATE: February 18, 2025 This site is zoned PAD-15. Food service is a permitted use in the PAD. 1. (Comment) Although the plans appears to match, final Site Zoning approval of this plan cannot occur until the submitted Revision 1 to the development package, TD-DEV-0224-00058, is approved. Once the revision to the DP is issued, please resubmit this building permit. Ensure the building permits match the approved development package (for example, inclusion, of new shade structures). RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Approval of Revision 1 to TD-DEV-0224-00058 and resubmittal of revised plans. If you have any questions about this transmittal, please contact Fernando L. Garcia at fernando.garcia2@tucsonaz.gov.
01/31/2025 PDSD Application Completeness Express REVIEW COMPLETED