| 09/12/2025 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 09/10/2025 | Commercial Structural Standard | REQUIRES RESUBMIT | Please submit your revised documents and provide a letter with a written response letter addressing each of the comments indicating how the Review comments were resolved. Please note the submittal was incomplete and the plan review was conducted using the information presented. The subsequent review could generate more comments after original comments have been addressed. 1. This is a commercial project, requiring all documents to be prepared, sealed, signed, and dated by a registered design professional and submitted in accordance with the City of Tucson Commercial Plan Submittal Requirements. Provide complete construction documents, plans, design, and calculations, sealed by an Arizona Registrant. Reference: Arizona Revised Statutes 32-125, Board of Technical Registration Rules R4-30-304, 2018 IBC section 107.1. City of Tucson Commercial Plan Submittal Requirements. https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/checklists/commercial_submittal_requirements_july2023.pdf THIS COMMENT PARTIALL REMAINS AND IS EXPANDED -please review and comply with our commercial submittal requirements. The structural calculations are sealed; however the construction drawings are not sealed by an Arizona licensed design professional as required. Please ensure these documents are sealed on the next submittal. IBC 107.2.1 2. THIS COMMENT IS COMPLETELY RESTATED; Provide architectural drawings as described in our submittal requirements. A Cover Sheets • General Project information including address, location map and square footage. A complete B. Code Analysis should also be present detailing the • type of construction, • occupancy • classification(s), • occupancy loads, • exiting requirements, • fire sprinklers and fire alarms. • Cover sheet must include a legend of symbols and abbreviations used throughout the plan set. C. Floor Plan • A fully dimensioned floor plan including room and/or suite numbers, showing all walls, • structural elements, proposed fire-resistant construction including details, and a complete and clear means of egress plan for each floor. D. Roof & Ceiling Plans • Show all elements, assemblies, draft stops, separations, and related information. F. Building and Wall Sections • Include all heights, materials of construction, non-related and fire-rated assemblies, and fire rated penetrations. G. Architectural Details • Include building sections, wall sections, waterproofing, fire proofing, weather proofing, door and window information, finishes, and accessibility requirements. F. Project Specifications • If not included in Plan Set Mark Masek Plans Examiner – Building Safety Planning and Development Services | City of Tucson main 520.837.4994 email mark.masek@tucsonaz.gov |
||
| 08/29/2025 | Site Engineering Standard | REQUIRES RESUBMIT | Permit: TC-COM-1124-02211 Location: 4301 E IRVINGTON RD Review Date: 8/29/2025 Site Engineering Comments: 1. This new structure on the site will require the submission of a development package per UDC Article 3.3.3.G.2.c. This will be a separate submission through TDC online under “Development Package.” 2. Permit TC-COM-1124-02211 will be unable to be approved until the development package is reviewed and approved by all reviewers. If you have any questions or concerns, please contact Marco Contreras Marco.contreras@tucsonaz.gov |
||
| 09/12/2025 | Site Zoning Standard | REQUIRES RESUBMIT | PDSD ZONING REVIEW TRANSMITTAL FROM: Bobby Parsons PDSD Site Zoning Review PROJECT: TC-COM-1124-02211 4301 E. Irvington Rd. Tucson, AZ 85714 Pre-Fab Warehouse (2nd Review) TRANSMITTAL DATE: 9/12/2025 Resubmit a detailed response letter, which states how all Zoning Review Section comments were addressed. This site is located in the I-2 zone (UDC 4.7.30). 1. Comment: Previous comment 1 not addressed. Per UDC Article 3.3.3.G.2.c, a site plan (Development Package) is required for the following types of development: Existing development undergoing a change of use, building structure additions, and/or a reconfiguration of an area outside a building. A Development Package (DP) meeting the requirements of the Checklist for Minor Changes to Commercial/Industrial Sites is required to be submitted and approved. The DP is a separate submittal from the building plans. The checklist can be found at: https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/permits/minor_changes_to_commercial_industrial_sites_.pdf. Site zoning is unable to approve this building permit until the DP has been approved by all reviewers. 2. Comment: Additional comments may be forthcoming depending on responses to zoning review comments and plans submitted. If you have any questions about this transmittal, please contact Bobby Parsons at Robert.Parsons@tucsonaz.gov. |
||
| 08/19/2025 | PDSD Application Completeness Express | REVIEW COMPLETED |