Permit Review Detail
Review Status: Requires Resubmit
Review Details: COMMERCIAL REVIEW - LIMITED v.1
Permit Number - TC-COM-1124-02164
Review Name: COMMERCIAL REVIEW - LIMITED v.1
Review Status: Requires Resubmit
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
12/06/2024 | Site Zoning | APPROVED | |||
12/10/2024 | Water - PDSD | APPROVED | |||
11/26/2024 | Site Engineering | NOT REQUIRED | |||
12/10/2024 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
11/27/2024 | Commercial Building | REQUIRES RESUBMIT | Sheet A1.0; For questions regarding Plan Review comments please contact: Dino M. Accardo, MCP, CBO, E: daccardo@willdan.com. Fire Plan Review is NOT within the scope of this review. All applicable comments will be followed with the initials, DMA. 1. Sheet A1.0, 2018 IBC 1004.5 Areas without fixed seating. The number of occupants shall be computed at the rate of one occupant per unit of area as prescribed in Table 1004.5. For areas without fixed seating, the occupant load shall be not less than that number determined by dividing the floor area under consideration by the occupant load factor assigned to the function of the space as set forth in Table 1004.5. Where an intended function is not listed in Table 1004.5, the building official shall establish a function based on a listed function that most nearly resembles the intended function. The occupant load proposed does not coincide with plans seating detailed. DMA 2. Sheet A1.1, 2018 IBC [P] 2902.1.1 Fixture calculations. To determine the occupant load of each sex, the total occupant load shall be divided in half. To determine the required number of fixtures, the fixture ratio or ratios for each fixture type shall be applied to the occupant load of each sex in accordance with Table 2902.1. Fractional numbers resulting from applying the fixture ratios of Table 2902.1 shall be rounded up to the next whole number. For calculations involving multiple occupancies, such fractional numbers for each occupancy shall first be summed and then rounded up to the next whole number Submit plumbing fixture calc that demonstrates shared common facilities is adequate for the tenant space AND building. DMA 3. Sheet A1.1, 2018 IBC [A]107.2.3 Means of egress. The construction documents shall show in sufficient detail the location, construction, size and character of all portions of the means of egress including the path of the exit discharge to the public way in compliance with the provisions of this code. In other than occupancies in Groups R-2, R-3, and I-1, the construction documents shall designate the number of occupants to be accommodated on every floor, and in all rooms and spaces. Provide plan details with travel distances that detail the discharge to the public way. DMA 4. Sheet M1.0, 2018 IBC 714.1.1 Ducts and air transfer openings. Penetrations of fire-resistance-rated walls by ducts that are not protected with dampers shall comply with Sections 714.3 through 714.4.3. Verify the existing building construction and intended design of corridor walls (fire-resistance rated). DMA |
||
11/27/2024 | Commercial Electrical | REQUIRES RESUBMIT | 1. Sheet E3.0, 2017 NEC; Provide a one line diagram and panel schedule that is for the dedicated panel/s and provides power for suite. DMA | ||
11/27/2024 | Commercial Mechanical | REQUIRES RESUBMIT | 1. Sheet M1.0, 2018 IBC 717.5.4.1 Corridors. Duct and air transfer openings that penetrate corridors shall be protected with dampers as listed within this section. DMA | ||
11/27/2024 | Commercial Plumbing | REQUIRES RESUBMIT | |||
11/22/2024 | Fire New Construction | REVIEW COMPLETED | |||
11/12/2024 | PDSD Application Completeness Express | REVIEW COMPLETED |