Permit Review Detail
Review Status: Requires Resubmit
Review Details: COMMERCIAL REVIEW - FULL v.1
Permit Number - TC-COM-1124-02148
Review Name: COMMERCIAL REVIEW - FULL v.1
Review Status: Requires Resubmit
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
12/09/2024 | Water - PDSD | APPROVED | |||
12/09/2024 | Bldg Permits - Post Review | PENDING ASSIGNMENT | |||
11/25/2024 | External Reviewers - SAFEBuilt | REQUIRES RESUBMIT | Structural(S) Reviewer Madeline Nelson mnelson@safebuilt.com Denied Reason: Date Completed : 11/22/2024 11:33:26 PM 1. GENERAL - UPDATES: For project updates, please submit sheets with all changes clearly marked in revision clouds. Please provide a written response to each comment; updates without a clear response to all comments may not be reviewed. If you have any questions regarding the comments, you may contact me directly. Updates may result in additional comments. 2. CANOPY PLANS - CONFLICTING INFORMATION: The canopy drawings provided by Lane Supply, Inc. call out member sizes that conflict with the structural calculations at the following locations. Please confirm the intended size of these members and amend the plans to match the calculation package: i. On the Order Canopy Sheet E1 of 4, the beam (W8x16) and outrigger sizes (W6) at the plan-east end of the canopy do not match "11-02174 ORDER CANOPY CALCS_v1.pdf", Page 15 of 15. Calculation package shows a W8x21 beam with W8x10 outriggers. ii. On the OMD Canopy Sheet AB2 of 2, the column is supported on a 1 1/4" thick base plate, which does not match "12-02174 OMD CANOPY CALCS_v1.pdf" Page 24 of 25. Calculation package shows a 2" base plate for each of the four columns. 3. CANOPY PLANS - CONFIRM CONNECTIONS: Please refer to Canopy Section A1-E2 for both canopies. These sections show W8 outriggers at either ends of the canopy that are supported by moment connections. These moment connections are achieved with 3-sides fillet welds onto the web, top and bottom flange of the adjacent perimeter beam. However, at some of these locations, the perimeter beams are W6's, which make the prescribed connection impossible. Please confirm how moment-fixity is achieved when the outrigger height and the beam heights are different. Building(B) Reviewer Andrew Bevis abevis@safebuilt.com Approved Reason: Date Completed : 11/22/2024 1:13:24 PM Mechanical(M) Reviewer Jorge Valido jvalido@safebuilt.com Denied Reason: Date Completed : 11/18/2024 12:53:28 PM 1. Plan Sheet M-201 - AC-2 Supply Air Drops total CFM quantity is 4850 CFM. Plan Sheet M401 on the ELECTRIC ROOFTOP UNIT SCHEDULE AC-2 states 4250 Total CFM. Confirm CFM for AC-2. - 2018 IECC Section C103.2Information on construction documents. - 2018 IBC – Section [A]107.2.1Information on construction documents. Electrical(E) Reviewer Ron Ross rross@safebuilt.com Approved with Comments Reason: Date Completed : 11/12/2024 5:34:29 PM 1. E-105 REMOTE MLOP CANOPY CONTROL PANEL was not shown in sheet index and is barely legible. 2. E-200 ELECTRICAL DEMOLITION PLAN could not locate Demolition Plan Keynotes 1 and 8. 3. E-202 LARGE SCALE KITCHEN POWER PLAN could not locate Power Plan Keynote 17 and other notes S6, S7, M2, and G3. 4. E-203 LARGE SCALE ADDITION POWER PLAN is missing Power Plan Keynotes 18,19, and 20. Plumbing(P) Reviewer Perry Hendershott phendershott@safebuilt.com Approved Reason: Date Completed : 11/17/2024 1:19:11 PM First Plumbing Review: OK |
||
11/25/2024 | Site Engineering | REQUIRES RESUBMIT | 1. The associated development package TD-DEV-1222-00060 must be approved before this building permit can be approved. Mike Ortiz michael.ortiz@tucsonaz.gov |
||
12/05/2024 | Site Zoning | REQUIRES RESUBMIT | FROM: PDSD Zoning Review PROJECT: TC-COM-1124-02148 - TD-DEV-1222-00060 4585 N ORACLE RD. – C-3 Food Service (1st Review) TRANSMITTAL DATE: December 5, 2024 Resubmit revised drawings along with a detailed response letter, which states how all Zoning Review Section comments were addressed. This site is located in the C-3 zone (UDC 4.7.22). Food Service is an allowed use in the zone (UDC Table 4.8-4). 1. Zoning has reviewed the building plans for compliance with Development Package (DP) TD-DEV-1222-00060 and although it appears the plans are consistent with each other until the DP is approved by all review agencies Zoning cannot approve this building permit. If you have any questions about this transmittal, please contact Zone1.desk@tucsonaz.gov. |
||
11/17/2024 | Fire New Construction | REVIEW COMPLETED | |||
11/08/2024 | PDSD Application Completeness | REVIEW COMPLETED |