Permit Review Detail
Review Status: Requires Resubmit
Review Details: COMMERCIAL REVIEW - FULL v.1
Permit Number - TC-COM-1124-02105
Review Name: COMMERCIAL REVIEW - FULL v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 11/18/2024 | Site Engineering | APPROVED | |||
| 11/27/2024 | Site Zoning | APPROVED | |||
| 12/05/2024 | Water - PDSD | APPROVED | |||
| 12/05/2024 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 11/14/2024 | Commercial Electrical | REQUIRES RESUBMIT | |||
| 11/14/2024 | Commercial Mechanical | REQUIRES RESUBMIT | 1. Sheet M2.00, 2018 IMC 504; Provide clothes dryer exhaust detail. DMA | ||
| 11/14/2024 | Commercial Plumbing | REQUIRES RESUBMIT | |||
| 11/14/2024 | Commercial Structural | REQUIRES RESUBMIT | Sheet c0.01; For questions regarding Plan Review comments please contact: Dino M. Accardo, MCP, CBO, E: daccardo@willdan.com. Fire Plan Review is NOT within the scope of this review. All applicable comments will be followed with the initials, DMA. 1. Sheet C0.01, 2018 IBC 1107.6.2.2.1 Type A units. In Group R-2 occupancies containing more than 20 dwelling units or sleeping units, at least 2 percent but not less than one of the units shall be a Type A unit. ALL Group R-2 units on a SITE shall be considered to determine the total number of units and the required number of Type A units. Type A units shall be dispersed among the various classes of units. Provide Type A and B calculation and dispersion. DMA 2. Sheet g0.08, 2018 IBC 714.2 Installation. A listed penetration firestop system shall be installed in accordance with the manufacturer’s installation instructions and the listing criteria. Provide on the plans the listing and installation instructions for firestop systems. DMA 3. Sheet a7.02, 2018 IBC1015.8 Window openings. Windows in Group R-2 and R-3 buildings including dwelling units, where the top of the sill of an operable window opening is located less than 36 inches above the finished floor and more than 72 inches (1829 mm) above the finished grade or other surface below on the exterior of the building, shall comply with one of the following: 1.Operable windows where the top of the sill of the opening is located more than 75 feet (22 860 mm) above the finished grade or other surface below and that are provided with window fall prevention devices that comply with ASTM F2006. 2.Operable windows where the openings will not allow a 4-inch-diameter (102 mm) sphere to pass through the opening when the window is in its largest opened position. 3.Operable windows where the openings are provided with window fall prevention devices that comply with ASTM F2090. 4.Operable windows that are provided with window opening control devices that comply with Section 1015.8.1. DMA 4. Sheet S1.0, 2018 IBC Ch 17; Provide Tucson Special Inspection Certificate. DMA 5. Sheet S1.0; Submit referenced Saeco soils report for this review. DMA |
||
| 11/17/2024 | Fire New Construction | REVIEW COMPLETED | |||
| 11/01/2024 | PDSD Application Completeness Express | REVIEW COMPLETED |