Permit Number: TC-COM-1123-02691
Parcel: 132131100

Review Status: Requires Resubmit

Review Details: COMMERCIAL REVIEW - FULL v.1

Permit Number - TC-COM-1123-02691
Review Name: COMMERCIAL REVIEW - FULL v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
12/20/2023 Bldg Permits - Post Review PENDING ASSIGNMENT
12/04/2023 External Reviewers - SAFEBuilt REQUIRES RESUBMIT Structural(S) Reviewer
Keith Miller
kmiller@safebuilt.com
Denied
Reason:
Date Completed : 12/1/2023 4:15:29 PM
See the building review comments.



Building(B) Reviewer
Keith Miller
kmiller@safebuilt.com
Denied
Reason:
Date Completed : 12/1/2023 4:13:59 PM
1) Sheet G0.0: Include all allowed vs actual building area, height, and number of stories. Include the areas under the roof/canopy, cooler, and trash enclosures. List all codes used in the design. (2018 IBC section 107)

2) Sheet S0.0: Provide the shear wall plans. 2018 IBC section 1603.1)

3) Sheet A1.2: The incorrect egress loading table and sections are stated for the 2018 IBC. (2018 IBC section 1004, Table 1004.5)

4) Sheet A2.1: Include the roof storm water drainage calculations. (2018 IPC Chapter 11)

5) Sheet A5.1: Show the toilet centerline distance from the side wall: (2009 ICC A117.1 section 604.2)

6) Sheet M1: Specify if the mechanical room is heated space. Show the mechanical room heat source, duct insulation or room insulations as applicable. (2018 IECC sections C402, C403.11)

7) Sheet M1: Show the vents for each fixture and the drain and vent sizes for each fixture. (2018 IPC section 106.3.1)

8) Sheet M1: Include the grease interceptor and interceptor vents on the layout and isometric plans. The floor sinks and hand sinks are to be connected to the grease interceptor. A sign stating “HANDWASH SINK ONLY! NO FOOD PREPARATION
OR DISHWASHING ALLOWED.” is to be posted if the hand wash sink is not connected to the grease interceptor. Please coordinate and revise the calculations and details on the plans. (2018 IPC section 1003.3)

9) Sheet M3.1: Provide the faucet specifications showing compliance with the requirements of 2018 IPC sections 412.11, 419.6)

10) Sheet E1.1: Show the air handler unit disconnects, cooler lights, receptacle, and disconnect. (2017 NEC sections 210.63, 210.70, 440.11)




Mechanical(M) Reviewer
Keith Miller
kmiller@safebuilt.com
Denied
Reason:
Date Completed : 12/1/2023 4:14:59 PM
See the building review comments.




Electrical(E) Reviewer
Keith Miller
kmiller@safebuilt.com
Denied
Reason:
Date Completed : 12/1/2023 4:14:42 PM
See the building review comments.



Plumbing(P) Reviewer
Keith Miller
kmiller@safebuilt.com
Denied
Reason:
Date Completed : 12/1/2023 4:15:16 PM
See the building review comments.
12/20/2023 Site Engineering REQUIRES RESUBMIT See zoning comment
12/05/2023 Site Zoning REQUIRES RESUBMIT ZONING REVIEW TRANSMITTAL

FROM: PDSD Zoning Review

PROJECT:
TC-COM-1123-02691
921 E TUCSON MARKETPLACE Bl. – PAD-15
Food Service – 7 Brew Coffee (1st Review)

TRANSMITTAL: December 5, 2023

Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review Section comments were addressed.

This site is located in PAD-15 (UDC 4.7.24). Food service is an allowed use in the PAD.

1. Per UDC Article 3.3.3.G.2.c A site plan (Development Package) is required for the following types of development: Existing development undergoing a change of use, building structure additions, and/or a reconfiguration of an area outside a building. A development package (DP) meeting the requirements of the Checklist for Minor Changes to Commercial/Industrial Sites is required to be submitted and approved. The DP is a separate submittal from the building plans. The checklist can be found at: https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/permits/minor_changes_to_commercial_industrial_sites_.pdf. Prior to submittal of the DP Design Review is required, see PAD-15 Section C.6.

2. The address this permit was submitted under, and the site location shown on the Vicinity Map does not appear to be correct. This address and parcel is currently occupied by a Whataburger with the address of 921 E TUCSON MARKETPLACE Bl. and there are no other addresses assigned to the parcel and there is no room for the proposed project. Clarify where you are proposing to build this project and resubmit under the correct address.

If you have any questions about this transmittal, please contact Zone1.desk@tucsonaz.gov.
12/12/2023 Water - PDSD REQUIRES RESUBMIT Show the location and size of the proposed water meter, backflow preventer, and the water service pipe on a site plan. The development package is not a substitute for a complete site plan. Reference: Section 107.2.1 and 107.2.6, IBC 2018.
11/22/2023 Fire New Construction REVIEW COMPLETED
11/21/2023 PDSD Application Completeness REVIEW COMPLETED