Permit Review Detail
Review Status: Requires Resubmit
Review Details: COMMERCIAL REVIEW - FULL v.1
Permit Number - TC-COM-1123-02686
Review Name: COMMERCIAL REVIEW - FULL v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 11/22/2023 | Commercial Electrical | APPROVED | |||
| 11/27/2023 | Commercial Mechanical | APPROVED | |||
| 11/27/2023 | Water - PDSD | APPROVED | |||
| 11/30/2023 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 11/27/2023 | Commercial Plumbing | REQUIRES RESUBMIT | Verify if an existing grease interceptor is currently in place to prevent the discharge of fats, oil, and grease into the public sewer. If a grease interceptor is not in place, show how the public sewer is to be protected from harmful discharges. Reference: Section 1003.1, IPC 2018. | ||
| 11/24/2023 | Commercial Structural | REQUIRES RESUBMIT | Submit your revised drawings along with a detailed response letter, which states how all Building Review Section comments were addressed. 1. Provide Glulam structural calculation sealed/signed/dated by a State of Arizona structural engineer registrant, including the following. Provide structural detail drawings at post to glulam connection, detail drawing at footing to post connection & footing detail, ledger detail drawing. 2. Proposed roof joist depth is not sufficient to accommodate required insulation. Provide R-38 insulation, proposed R-19 is not sufficient. 3. Provide detail drawing of the roof connection above the new ledger, clearly showing compliant flashing detail preventing water leak into new space. 4. Provide concrete slab in front of the new front door. 5. Provide drawings depicting the accesible counters complying to the ANSI requirement for both shoppers and employees. 6. Please resubmit. |
||
| 11/30/2023 | Site Engineering | REQUIRES RESUBMIT | See zoning comments | ||
| 11/21/2023 | Site Zoning | REQUIRES RESUBMIT | ZONING REVIEW TRANSMITTAL FROM: PDSD Zoning Review PROJECT: TC-COM-1123-02686 3840 E. 22nd St. – C-3 General Merchandise Sales (1st Review) TRANSMITTAL: November 21, 2023 Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review Section comments were addressed. This site is located in the C-3 zone (UDC 4.7.22). General Merchandise Sales, excluding Large Retail Establishment is an allowed use in the zone (UDC Table 4.8-4), subject to Use Specific Standard 4.9.9.B.1. 1. Per UDC Article 3.3.3.G.2.c A site plan (Development Package) is required for the following types of development: Existing development undergoing a change of use, building structure additions, and/or a reconfiguration of an area outside a building. A development package (DP) meeting the requirements of Administrative Manual (AM) 2-06 must be submitted and approved prior to approval of this building plan. If you have any questions about this transmittal, please contact Zone1.desk@tucsonaz.gov. |
||
| 11/22/2023 | Fire New Construction | REVIEW COMPLETED | |||
| 11/20/2023 | PDSD Application Completeness Express | REVIEW COMPLETED | This project is part of TC-COM-0123-00505 |