Review Status: Requires Resubmit

Review Details: COMMERCIAL PDSD SIMPLE REVIEW v.1

Permit Number - TC-COM-1123-02663
Review Name: COMMERCIAL PDSD SIMPLE REVIEW v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
11/16/2023 Bldg Permits - Post Review Express PENDING ASSIGNMENT
11/16/2023 Commercial Electrical REQUIRES RESUBMIT Permit Review TC-COM-1123-02656 (1625 W FORT LOWELL RD Unit:UNIT 59-66 TUCSON, AZ 85705)
TC-COM-1123-02657
TC-COM-1123-02658
TC-COM-1123-02659
TC-COM-1123-02660
TC-COM-1123-02661
TC-COM-1123-02662
TC-COM-1123-02663
Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide updated Plans/calculations and a written response Letter to each of the notated items indicating action taken. Resubmitted plans that do not contain a written response Letter addressing each of the notated items indicating action taken, may be delayed until response letter is received.
Code reference, 2018 International Building Code (IBC), 2017 National Electrical Code (NEC).

1. Show the unit number on the site plan for each service meter.
2. Provide a grounding detail in compliance with NEC 250. Show grounding rods(2x) at each new Mobile home panelboard, NEC 250.32(A).
3. Show on the plans that each of the new Mobile home panelboards shall be suitable for use as service equipment, per NEC 550.32.

Contact Jeremy Hamblin with any questions: Jeremy.hamblin@tucsonaz.gov
11/14/2023 PDSD Application Completeness Express REVIEW COMPLETED Shared Studio Session on 906-969-673 Master Permit is TC-COM-1123-02656 relocate the pedestal to a meter pack. Permits running off Master Permit Plan set TC-COM-1123-02657, TC-COM-1123-02658, TC-COM-1123-02659, TC-COM-1123-02660, TC-COM-1123-02661, TC-COM-1123-02662 & TC-COM-1123-02663.