Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: TC-COM-1123-02638
Parcel: 13014024A

Address:
4202 E 22ND ST

Review Status: Requires Resubmit

Review Details: COMMERCIAL REVIEW - FULL v.4

Permit Number - TC-COM-1123-02638
Review Name: COMMERCIAL REVIEW - FULL v.4
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
02/05/2024 Bldg Permits - Post Review Express PENDING ASSIGNMENT
02/05/2024 External Reviewers - SAFEBuilt REQUIRES RESUBMIT Structural(S) Reviewer
Keith Miller
kmiller@safebuilt.com
Approved
Reason:
Date Completed : 1/19/2024 5:01:54 PM
Structural review is approved. Subject to the field inspector's approval.



Building(B) Reviewer
Keith Miller
kmiller@safebuilt.com
Approved
Reason:
Date Completed : 2/2/2024 1:46:21 PM
Building review is approved. Subject to the field inspector's approval.



Mechanical(M) Reviewer
Keith Miller
kmiller@safebuilt.com
Approved
Reason:
Date Completed : 1/19/2024 4:55:08 PM
Mechanical review is approved. Subject to the field inspector's approval.



Electrical(E) Reviewer
Keith Miller
kmiller@safebuilt.com
Approved
Reason:
Date Completed : 1/19/2024 4:54:29 PM
Electrical review is approved. Subject to the field inspector's approval.



Plumbing(P) Reviewer
Keith Miller
kmiller@safebuilt.com
Denied
Reason:
Date Completed : 2/2/2024 1:48:57 PM
1) Resolved – General: Areas under the roof are to be included in the building area/fire area and occupant loads greater than 99 require sprinklers per 2018 IBC section 903.2.1.2 #2. If sprinklers are being installed and deferred, include a list of
deferred submittals on the cover sheet.

2) Unresolved - Sheet P-102, P-401: A hand wash sink is not connected to the grease interceptor piping and requires signage stating “HANDWASH SINK ONLY! NO FOOD PREPARATION OR DISHWASHING ALLOWED.”. The hydromechanical grease interceptor cannot be used for more than 4 fixtures. Please revise all affected sheets and provide the grease interceptor calculations. (2018 IPC amended section 1003.3) – Please provide a letter from the building official if the amended grease interceptor requirements are being waived.

3) Resolved - Sheet P-402: Provide the water supply piping calculations. (2018 IPC section 604)

4) Resolved - Sheet G002: The toilet facilities do not have a lavatory located in the room. Please revise all affected sheets, details, and calculations. (2018 IBC sections 2902.3, 1109.2.1, 2018 IPC Toilet Facility definition, section 405.3.2)

5) Resolved - Sheet P-102: Provide the drainage fixture unit calculations for the drain and vent pipe sizing. (2018 IPC sections 710, 906)
02/01/2024 PDSD Application Completeness Express REVIEW COMPLETED