Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit Review Detail
Review Status: Requires Resubmit
Review Details: COMMERCIAL REVIEW - FULL v.2
Permit Number - TC-COM-1123-02615
Review Name: COMMERCIAL REVIEW - FULL v.2
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 01/02/2024 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 12/28/2023 | Site Zoning | REQUIRES RESUBMIT | FROM: Paul Camarena PDSD Zoning Review Section PROJECT: TC-COM-1123-02615– Tenant Improvement Building Plan Review (2nd Review) 5101 N Oracle Rd / C-3 Zone TRANSMITTAL DATE: 12/28/2023 1.COMMENT: Zoning has reviewed the building plans for compliance with the associated Development Package TD-DEV-1023-00433. Zoning cannot approve the building plans until the DP is approved. 2. COMMENT: Zoning will review the TI on the next submittal to ensure consistency with the Development Package. Resubmittal instructions: https://www.tucsonaz.gov/files/sharedassets/public/pdsd/documents/tdc-faq/new-pdfs/revisions-and-resubmittals.pdf If you have any questions about this transmittal, Contact Paul Camarena at (520) 837-4986 or by email: Paul.camarena@tucsonaz.gov |
||
| 01/02/2024 | External Reviewers - SAFEBuilt | REVIEW COMPLETED | Structural(S) Reviewer Madeline Nelson mnelson@safebuilt.com Approved Reason: Date Completed : 12/27/2023 5:13:11 PM Building(B) Reviewer Andrew Bevis abevis@safebuilt.com Approved Reason: Date Completed : 12/27/2023 5:28:34 PM Mechanical(M) Reviewer Jorge Valido jvalido@safebuilt.com Approved Reason: Date Completed : 11/21/2023 6:56:02 PM Electrical(E) Reviewer Ron Ross rross@safebuilt.com Approved Reason: Date Completed : 12/26/2023 5:01:57 PM Plumbing(P) Reviewer Perry Hendershott phendershott@safebuilt.com Approved Reason: Date Completed : 12/31/2023 8:04:18 PM Third plumbing Review: OK Resolved-1). Roof Drainage sizing table on A3.0 is missing information for several roof areas. -IPC 1106.2. 1106.3, 1106.5, 1108 Resolved-2). Add Gas riser Diagram to plumbing pages for clarity - IFGC 106.3.1 Resolved-3). Add gas sizing table used to plan pg. P1.2 -IFGC 402.3 Resolved-4). Add Water heater manufacturer name & Model to Plan page P2.0 - IPC 501.5 Resolved-5). Plumbing pages missing Primary & secondary Roof drain conductor illustrations along with sizing calculations as stated on plan page A3.0 -IPC 1106.2 Resolved-6). Plan page P2.0 schedule missing roof drains & overflow info -IPC 1102.6 |
||
| 12/22/2023 | PDSD Application Completeness Express | REVIEW COMPLETED |