Permit Review Detail
Review Status: Requires Resubmit
Review Details: COMMERCIAL REVIEW - FULL v.1
Permit Number - TC-COM-1123-02603
Review Name: COMMERCIAL REVIEW - FULL v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 12/12/2023 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 11/29/2023 | External Reviewers - SAFEBuilt | REQUIRES RESUBMIT | Structural(S) Reviewer Madeline Nelson mnelson@safebuilt.com Denied Reason: Date Completed : 11/28/2023 9:51:30 PM 1. GENERAL - STRUCTURAL DRAWINGS: Please submit a full set of construction drawings as required per the 2018 International Building Code, Section 107 and 1603. Construction drawings must fully describe the structural members and all information pertinent to the structural design, and must be sealed by a professional engineer licensed in the State of Arizona. 2. GENERAL - SPECIAL INSPECTIONS: Please have the Registered Design Professional in Responsible Charge of this project complete and return the City of Tucson Special Inspections Certificate with signatures. The form can be downloaded at: https://www.tucsonaz.gov/files/sharedassets/public/city-services/planning-developmentservices/documents/special_inspection_certificate.pdf 3. GENERAL - GEOTECHNICAL REPORT: Please provide a copy of the site-specific geotechnical report for this project. The report should support the appropriateness of the selected foundation system for the project site. All building code references must be updated to the current code adopted by the City. 4. GENERAL - STRUCTURAL CALCULATIONS: With the construction documents, please provide calculations supporting selection of all structural members, including foundation designs and all lateral elements. Calculations should clearly indicate all surface loads considered and provide beam summary sheets noting that all beams have passed the analysis. Building(B) Reviewer Keith Miller kmiller@safebuilt.com Denied Reason: Date Completed : 11/21/2023 4:39:02 PM Unable to complete the review. No building plans submitted. 1) General: Please submit the full set of construction drawings including a cover sheet with the occupancy classification, occupant load and calculations, construction type, minimum, allowed vs actual height, area, and number of stories, plumbing fixture calculations, scope of work, loads used in the design, etc. (2018 IBC section 107) Mechanical(M) Reviewer Jorge Valido jvalido@safebuilt.com Denied Reason: Date Completed : 11/21/2023 12:57:10 PM 1. General - Provide Minimum Design Criteria - 2018 IECC Section C103.2 Information on Construction Documents 2. General - Provide Ventilation Calculations/Schedule - 2018 IMC Section Table 403.3.1.1 3. General - Provide Energy Calculations - Mechanical Compliance Certificate - Section C403 Building Mechanical Systems Electrical(E) Reviewer Ron Ross rross@safebuilt.com Denied Reason: Date Completed : 11/27/2023 6:12:18 PM Electrical Review By: Ron Ross PE Electrical Permit id Denied. No electrical design has been submitted. An electrical design should include all of the following: An Electrical One Line/Riser Load calculations and lighting comchecks as well as the City of Tucson's exterior lumens calculation. Panel schedules. Circuits/homeruns from electrical equipment shown on plans showing required NEC compliance ie GFCI protection etc. Drawings to be signed and sealed by a licensed professional and an electrical PE if the electrical service is over 400 amps. Tucson requires Short circuit calculations for all panels. Obtain Short circuit information of service from local Utility company. Include any pertinent drawings or calculations. Plumbing(P) Reviewer Perry Hendershott phendershott@safebuilt.com Denied Reason: Date Completed : 11/26/2023 8:09:30 PM First Plumbing Review: 1). Provide Complete plan set with plumbing & Gas drawings-IPC 106.3.1 2). Address Bldg Plan review comment #1-IPC 106.3.1, 403.1 |
||
| 12/11/2023 | Fire New Construction | REQUIRES RESUBMIT | -Submit complete set of building plans for review. john.vincent@tucsonaz.gov 5203495581 |
||
| 12/12/2023 | Site Engineering | REQUIRES RESUBMIT | See zoning comment | ||
| 11/29/2023 | Site Zoning | REQUIRES RESUBMIT | ZONING REVIEW TRANSMITTAL FROM: PDSD Zoning Review PROJECT: TC-COM-1123-02603 2545 N. Fairview Av. – I-1 General Manufacturing – New Building (1st Review) TRANSMITTAL: November 29, 2023 Please resubmit revised drawings along with a detailed response letter, which states how all Zoning Review Section comments were addressed. This site is located in I-1 (UDC 4.7.29). General Manufacturing is an allowed use in the zone (UDC Table 4.8-5) subject to Use Specific Standards 4.9.5.C.2, .6, .7, & .8 and 4.9.13.Q. 1. The submitted plans appear to be site only and per UDC Article 3.3.3.G.2.c A site plan (Development Package) is required for the following types of development: Existing development undergoing a change of use, building structure additions, and/or a reconfiguration of an area outside a building. A development package (DP) meeting the requirements of Administrative Manual (AM) 2-06 must be submitted and approved prior to approval of this building plan. The DP is submitted at: https://tdc-online.tucsonaz.gov/#/home, using category Development Package. The DP is a separate submittal form the building plans. If you have any questions about this transmittal, please contact Zone1.desk@tucsonaz.gov. |
||
| 12/05/2023 | Water - PDSD | REQUIRES RESUBMIT | 1. Verify the pad and FFE elevations for the proposed building. Drawings C1.0 and C1.1 show a pad elevation of 2292.55’ and a FFE of 2293.33’ while drawing C2.0 shows a pad elevation of 2337.8’ and a FFE of 2338.5’. The elevation contour shown running through the building on C2.0 is 2340’. (The grading plan key notes appear to be for a house in Peoria.) 2. Reduced pressure backflow prevention assemblies are required at the water meter for multi-use commercial buildings. Reference: Chapter XXVII, Article V, Section 27-72, the Tucson Code, https://www.tucsonaz.gov/files/sharedassets/public/city-services/tucson-water/water-quality/documents/backflow-ordinance.pdf |
||
| 11/13/2023 | PDSD Application Completeness Express | REVIEW COMPLETED |