Permit Number: TC-COM-1123-02586
Parcel: 12402058A

Address:
1615 E 2ND ST

Review Status: Requires Resubmit

Review Details: COMMERCIAL REVIEW - FULL v.1

Permit Number - TC-COM-1123-02586
Review Name: COMMERCIAL REVIEW - FULL v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
12/04/2023 Water - PDSD APPROVED
12/14/2023 Bldg Permits - Post Review Express PENDING ASSIGNMENT
11/15/2023 External Reviewers - SAFEBuilt REQUIRES RESUBMIT Structural(S) Reviewer
Keith Miller
kmiller@safebuilt.com
Denied
Reason:
Date Completed : 11/15/2023 4:07:33 PM
See the building review comments.



Building(B) Reviewer
Keith Miller
kmiller@safebuilt.com
Denied
Reason:
Date Completed : 11/15/2023 4:05:54 PM
1) General: Provide the energy code compliance details for the walls, ceiling/roof, windows and doors, meeting the requirements of the 2018 IECC section R402. Include the R-Vaues and U-factors of al components. Can also provide a REScheck for trade-offs. Revise all affected sheets.

2) Sheet 1: Detail if sprinklers or a fire alarm system is being installed. Include a list of deferred submittals and any special inspections. (2018 IBC section 107)

3) Sheet a2.0: Include the roof drainage system. (2018 IPC section 1101)

4) Sheets a4.0 and a9.2: Asphalt shingles are to be fastened to solidly sheathed decks. Provide the details showing the method of fastening the shingles and underlayment through the rigid foam board on top of the sheathing meeting the
requirements of the installation instructions of the shingles and underlayment. For roof pitches between 2:12 and 4:12, a minimum of two layers of underlayment is required. Revise all applicable sheets. (2018 IBC sections 1507.1, 1507.2)

5) Sheets a4.0 and a9.2: Asphalt shingles are not allowed on roof pitches less than 2:12. Revise all aplicable sheets. (2018 IBC section 1507.2)

6) Sheets a1.0 and a8.0: Show safety glazed windows in hazardous locations near tub and door on the floor plans and window schedule. Provide the window schedule specifying window types, U-factors, and if safety gazed. (2018 IBC section
2406.4, 2018 IECC section R402)

7) Sheet m1.0: Show the sources of combustion air for the clothes dryer and the water heater. Include the design and calculations. (2018 IFGC section 304)

8) Sheet e2.0: Missing receptacles on the front of the unit and at the rear patio. (2017 NEC section 210.52(E)(2) and (3)



Mechanical(M) Reviewer
Keith Miller
kmiller@safebuilt.com
Denied
Reason:
Date Completed : 11/15/2023 4:06:59 PM
See the building review comments.



Electrical(E) Reviewer
Keith Miller
kmiller@safebuilt.com
Denied
Reason:
Date Completed : 11/15/2023 4:06:43 PM
See the building review comments.



Plumbing(P) Reviewer
Keith Miller
kmiller@safebuilt.com
Denied
Reason:
Date Completed : 11/15/2023 4:07:15 PM
See the building review comments.
12/06/2023 Fire New Construction REQUIRES RESUBMIT Address SAFEBuilt comments.
Questions: patricia.shelton@tucsonaz.gov
12/14/2023 Site Engineering REQUIRES RESUBMIT A development package is required prior to approval of this building permit.
Joshua Garcia
joshua.garcia@tucsonaz.gov
11/17/2023 Site Zoning REQUIRES RESUBMIT ZONING REVIEW TRANSMITTAL

FROM: PDSD Zoning Review

PROJECT:
TC-COM-1123-02586
1615 E. 2nd St. – R-3
(1st Review)

TRANSMITTAL: November 7, 2023

Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review Section comments were addressed.

This site is located in the R-3 zone (UDC 4.7.20). A Religious Use is an allowed use in the zone (UDC Table 4.8-2).

1. Per UDC Article 3.3.3.G.2.c A site plan (Development Package) is required for the following types of development: Existing development undergoing a change of use, building structure additions, and/or a reconfiguration of an area outside a building. A development package (DP) meeting the requirements of Administrative Manual (AM) 2-06 must be submitted and approved prior to approval of this building plan. Zoning was not able to find a development package submittal for the DP sheets provided in the plan set.

2. The DP sheets submitted in the building plans shall either be the stamped approved plans, or marked as for reference only, or removed from the plan set.

If you have any questions about this transmittal, please contact Zone1.desk@tucsonaz.gov.
11/08/2023 PDSD Application Completeness Express REVIEW COMPLETED